ABC Kliima ELK 9M Скачать руководство пользователя страница 1

01.12.2017

ELK 9M

Installer manual

Immersion heater

Содержание ELK 9M

Страница 1: ...01 12 2017 ELK 9M Installer manual Immersion heater ...

Страница 2: ......

Страница 3: ..._____________ 4 Assembly__________________________________ 5 Component positions_________________________ 5 Pipe connections____________________________ 6 Electrical connection_________________________ 8 Activating ELK 9M__________________________ 10 Technical data_____________________________ 11 ...

Страница 4: ...ve penalties in accordance with current legislation General ELK 9M is an electric heater that can be used to sup plement the heating capacity of your MHI climate unit When the heating demand is greater than the climate unit s capacity the electric heater connects automat ically The electrical equipment is adapted to the cli mate unit s function The electric heater is in principle an immersion heat...

Страница 5: ...le detachable connections must be used Component positions Component list EB1 Immersion heater FD1 Overheat protection X1 Terminal block QA1 Contactor 3 0 kW K1 QA2 Contactor 6 0 kW K2 BT30 Emergency mode thermostat XL1 Connection supply line G 32 XL2 Connection return line G 32 UB1 UB2 Cable gland QM60 Venting PF1 Rating plate XL1 EB1 XL2 UB1 UB2 PF1 X1 QA1 QA2 BT30 FD1 QM60 ...

Страница 6: ...E The pipe work must be flushed before the electric heater is connected so that any contaminants do not damage the component parts CAUTION Also see the installer manual for your heat pump in door module Draining The system is most easily drained by installing a drainage valve at the lowest point on the pipe instal lation The remaining water in ELK 9M is drained through the return line connection X...

Страница 7: ...pump RM5 Non return valve BT25 Flow line sensor BT71 Return line sensor Designations in component locations according to standard IEC 81346 1 and 81346 2 System diagram BT25 BT71 GP10 RM5 QM41 QM40 FL2 CM4 EB1 Värmepump Inomhusmodul RN11 Heat pump Indoor module NOTE This is an outline diagram Actual installations must be planned according to applicable standards ...

Страница 8: ...rdance with the stipulations in force The climate unit must not be powered when installing ELK 9M ELK 9M must be installed via a circuit breaker with a minimum breaking gap of 3mm ELK 9M contains overheat protection and two con tactors to control the two power steps 3 kW and 6 kW respectively For best function the power should be binary controlled that is to say 3 6 and 9 kW ...

Страница 9: ...active power steps LEK X1 1 1 0 PE X2 1 6 5 4 3 2 1 2 3 4 5 6 X1 AA7 X2 L N 2 3 4 SMO ELK 2 3 4 1 0 PE J1 2 J1 1 J2 2 X9 X1 AA7 X2 ELK 9M Contr ol module X1 X1 AA7 X2 1 2 3 4 5 6 9 kW electric heater step active 6 kW electric heater step active in emergency mode With thermostat two active power steps SMO ELK 2 3 4 1 0 PE J1 2 J1 1 8 J2 2 X9 X1 AA7 X2 ELK 9M Contr ol module X1 X1 AA7 X2 1 2 3 4 5 6...

Страница 10: ... will be connected to Start guide The start guide appears upon first start up after heat pump installation but is also found in menu 5 7 Menu system RC HY 20 and RC HY40 Menu 4 9 3 degree minute setting Here you select when the additional heat is to start and the degree minute intervals Menu 5 1 12 addition Setting Max number of permitted additional steps If binary stepping is to be used ...

Страница 11: ...11 ELK 9M Technical data Dimensions All dimensions in mm 181 128 56 111 244 28 604 144 5 350 ...

Страница 12: ...use A 13 Enclosure class IP21 Heating medium circuit Max permitted pressure in the boiler MPa bar 0 7 7 Min flow l h 650 Max flow l h 2600 Dimensions and weight Width mm 244 Depth mm 111 Height mm 604 Weight kg 10 5 Volume litre 1 5 Miscellaneous Material immersion heater SIS 2333 EN 1 4301 Material tube P235GH PN EN 10216 2 Part No MCD291A015 ...

Страница 13: ...put For boiler space heaters and boiler combination heaters Useful efficiency At rated heat output and high temperatu re regime P4 15 kW At rated heat output and high tempe rature regime ƞ4 40 At 30 of rated heat output and low tem perature regime P1 kW At 30 of rated heat output and low temperature regime ƞ1 Auxiliary electricity consumption Other items At full load elmax kW Standby heat loss Pst...

Страница 14: ...14 ELK 9M Electrical circuit diagram K1 K2 3x1 5kW 3x1 5kW Immersion heater FD1 98 8 C 400V 3 50Hz L3 L2 L1 PE K2 K1 J1 2 J1 1 8 J2 1 BT30 5 80 C A1 A2 A1 A2 N 1 3 5 2 4 6 1 3 5 6 4 2 8 7 X1 ...

Страница 15: ......