2104349 rev. AD
Page 4
–3
Figure 4
–1 Reset Button Location
2) Upon location, press the Reset button for approximately five seconds. The
unit will warm boot.
4.4.1.2
Method 2
1) Open the door to the unit. Ensure that there is voltage on the battery and
that the jumper is enabled.
If either of these conditions are not met, do not attempt a
warm boot. Continuing with this process without both
conditions being met will result in a cold boot and all
historical data will be lost.
2) Remove power to the board, and then reconnect. This will initiate a warm
boot.
4.4.2 Software Warm Boot
There are three methods of warm booting the system from a software standpoint:
4.4.2.1
Method 1
1) Open PCCU32. The user needs to ensure that they are not connected
initially and are at the Totalflow splash screen.
2) Click the 32-Bit Loader icon on the toolbar. This takes the user to the 32-Bit
Loader screen.
3) Within the screen, the user needs to select the Reload radio button.
4) Ensure that all of the checkmarks are removed from the various software
option. Once this has been accomplished, place a check in the options list
beside Shutdown Flash and Start Flash.
5) Select the needed connection type from the available drop-down menu.
6) Upon completion, click the Start button.
S3
3
J9
1
COMM1
1
J19
J16
PWR
-
+
2
3
4
6
8
1
2
RESET
7
9
5
Содержание XSeries G4 6200
Страница 41: ...2104349 rev AD Page 1 27 Figure 1 22 Ethernet communication cable Figure 1 23 Ethernet connectivity diagram ...
Страница 42: ......
Страница 61: ...2104349 rev AD Page 2 19 Figure 2 18 G4 EX to UPS ...
Страница 62: ......
Страница 130: ......
Страница 163: ...2104349 rev AD Page 33 ...