2106001MNAA | XSERIES G5 START UP GUIDE | 51
Table 8-1: Required Station Setup
Entry
Format
Description
Station
ID
10 digit
alphanumeric
The station identifier code is unique. If
running a multiple tube station, the station
ID is the same for all tubes on the device. If
left blank on a single tube device, the
station ID will be the same as the device ID.
Location
24 digit
alphanumeric
The location identifier describes the
location, such as the county name or a road
number. Not mandatory.
Date/
Time
MM/DD/YYYY
HH:MM:SS
(24 hour clock)
Date and time must be set correctly and
should agree with the collection equipment
if measurement tubes are instantiated.
1.
Verify the Lithium Battery Status is OK with a green bar, see
. If the status is Low Voltage or Not
Connected, the field background color is red.
2.
Change settings in the Station Setup tab as needed. Leave PCCU open
on the Station Setup tab. For more information, refer to the XFC or
XRC user manual.
Change the default time and date format
The factory configuration has a default date and time displayed on the
LCD.
Change the default format to preferred settings:
1.
On the
Station Setup
tab, scroll down to the LCD Display Date/Time
Format. See the figure below.
Figure 8-2: Station Setup Detail
2.
Select the preferred Date/Time Format (mmddyy or yymmdd).
3.
Select the preferred Date Separator (slash, dash, or period).
4.
Select the preferred Time Separator (colon or period).
5.
Click
Send
to save all station settings.