background image

VER:1.1  │     │  10.09.2015 

  

ABB-Welcome 

 

 

 

Pos :  2 /Di nA4 -  Anleit ung en O nline/I nhalt /KN X/D oorEntr y/ 83220- AP- xxx/Tit elbl att  - 83220-AP- xxx -  ABB  @  19\ mod_1323249806476_15. doc x @  111084 @   @  1 

 

M25102xC 
M25102xA-x- 
M25102xPx. 
M25102xK-x. 
M25102xCR. 
5102xDN 
5101xPx 
Outdoor station

 

  

Содержание Welcome M25102 C Series

Страница 1: ...elcome Pos 2 Di nA4 Anleitung en Online Inhalt KN X D oorEntr y 83220 AP xxx Titelbl att 83220 AP xxx ABB 19 mod_1323249806476_15 docx 111084 1 M25102xC M25102xA x M25102xPx M25102xK x M25102xCR 5102xDN 5101xPx Outdoor station ...

Страница 2: ...Round pushbutton 2 button Camera module Round pushbutton 1 button Round pushbutton 3 button Pushbutton 3 6 button Pushbutton 4 8 button Round pushbutton 1 button with NFC IC Display with ID Display with IC Round pushbutton 2 button with NFC IC Round pushbutton 3 button with NFC IC Keypad 3 versions Stainless steel Aluminum White ...

Страница 3: ...ion 27 5 1 Pushbutton outdoor station 27 5 1 1 Addressing 27 5 1 2 Setting the language for the voice messages if the audio module has a speech synthesis function 31 5 2 Pushbutton outdoor station with display module 34 5 3 Pushbutton outdoor station with keypad module 36 5 4 Round pushbutton outdoor station with IC NFC 38 5 5 Keypad outdoor station 42 5 5 1 Call a resident 3 types 42 5 5 2 Call t...

Страница 4: ...ABB Welcome 4 8 1 Requirements for the electrician 60 8 2 General installation instructions 61 8 3 Mounting 62 Ende der Liste fü r Textmar ke TOC ...

Страница 5: ...ts from this system The device must only be used with suitable ABB flush mounted installation sockets and rain hood Pos 10 Busch Jaeg er Neustr uktur Modul Struktur Online Dokumentati on Überschriften Fü r alle D okumente 1 Ebene U Z U mwelt 18 mod_1302614158967_15 docx 103383 1 1 3 Environment Pos 11 Busch Jaeg er Neustr uktur Modul Struktur Online Dokumentati on U mwel t Fü r alle D okumente Hin...

Страница 6: ...the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EG WEEE and 2002 95 EG RoHS EU REACH ordinance and law for the implementation of the ordinance EG No 1907 2006 ...

Страница 7: ... 1 Audio module No Function 1 LED flashes slowly indicating a call has been established LED flashes fast indicating that the system is busy 2 LED illuminates indicating possible communication 3 LED illuminates indicating the door is unlocked 4 Call pushbuttons ...

Страница 8: ... loop module 8 Connector for next module 9 Connector for exit push button 10 Connector for sensor for checking the door status 11 Rotary switch for setting the address of OS 1 9 12 Set feedback tones for push buttons and for outdoor station when making a call ON OFF 13 Configure push buttons in a single column or double column mode ON double column OFF single column It only affects the bar pushbut...

Страница 9: ...tion 9 3 OFF 4 ON call guard unit call indoor station 3 ON 4 ON switch on lighting call guard unit 15 Adjust the loudspeaker volume 16 Adjust the door lock release time 1 10s available for the lock connected with the default lock ...

Страница 10: ...rminal description 10 Default lock 1st lock Released by Unlock button of the indoor station Factory setting is LOCK GND 2nd lock Released by programmable button 1 of the indoor station Factory setting is COM NC NO 1 ...

Страница 11: ...ing mode 3 LED flashes green to show the setting mode for aluminum outdoor station prompt tone di for stainless outdoor station Tones for indication Lock 1 LOCK GND default lock Lock 2 NC NO COM default lock Set outdoor station address 0 30s overtime to save the setting and exit the programming mode Short circuit Exit terminal on outdoor station to switch the default lock ...

Страница 12: ...o enter the setting mode 3 LED flashes green to show the setting mode for aluminum outdoor station Prompt tone di for stainless outdoor station Set outdoor station address 0 Record the time for 1st lock Then set the time for 2nd Lock from 1 10s 30s overtime to save the setting and exit the programming mode At last set the time back for 1st Lock Recover the time to the original time for 1st lock ...

Страница 13: ...ABB Welcome Terminal description 13 4 1 1 Lock connected with terminals 3 and 4 ...

Страница 14: ...lcome Terminal description 14 4 2 Camera module No Functions 1 Connector for additional analog camera 2 Connector for audio module 3 Jumper for setting the video format PAL NTSC 4 Adjust the camera view area ...

Страница 15: ...st signal can be connected with the camera module Generally the transmission distance from the analog camera to the outdoor station can reach up to 50 meters by coax cables or about 10 meters by other types of cables Two types of connections Option 1 The analog camera is powered on all the time Option 2 The analog camera is powered on only during working hours ...

Страница 16: ...ABB Welcome Terminal description 16 4 2 2 Detached camera connection Camera module can be used as a detached camera Wiring is shown below 3 pairs 2 wire bus together Max 10 metres ...

Страница 17: ...ushbutton module No Functions 1 Program button 2 Connector for previous module 3 Connector for device software update 4 Connector for Wiegand output Default format is 26 bits it can also be extended to 34 bits 5 Connector for next module 1 2 3 4 5 2 ...

Страница 18: ...hting switch call guard unit function is always assigned to the 1st 2nd button which is set by audio module 3 User names can be printed by using the labellling tool of the ABB Welcome configuration software 4 The round pushbutton module with NFC IC card reader supports the NFC IC card A mobile phone with NFC function is acceptable Door Open APP required ...

Страница 19: ...ton module No Functions 1 Connector for previous module 2 Connector for next module No Functions 1 Regardless of the structure of the pushbutton module the button numbers are listed from top to bottom and from left to right in the double column mode ...

Страница 20: ...e Terminal description 20 2 Lighting switch call guard unit function is always assigned to the 1st 2nd button 3 User names can be printed by the using the labelling tool of the ABB Welcome configuration software ...

Страница 21: ...tion 21 4 5 Keypad module No Functions 1 Program button 2 Connector for previous module 3 Connector for device software update 4 USB connector for connection to the PC Download upload the configuration 5 Connector for next module ...

Страница 22: ...ble in Fig 1 2 Calling the guard unit A visitor can call a guard unit by pressing the button if the guard unit is available in the system 3 Unlocking by password Press password to release the default lock to the audio module Press 2 password to release the 2nd lock connected to the audio module The initial password is 123456 Residents can set their own customized password with indoor stations 4 Sy...

Страница 23: ...der module No Functions 1 Program button 2 Connector for previous module 3 Connector for device software update 4 Connector for Wiegand output 5 USB connector for connecting to the PC Download upload the Configuration 6 Connector for the next module No Functions ...

Страница 24: ...rogrammed through the module itself or by using a PC to download the program file M251021CR is accompanied with an ID card reader while the M251022CR is accompanied with an IC card reader 3 Support Wiegand output The default Wiegand format is 26 bits but it can also be extended to 34 bits The display module must be connected after audio module ...

Страница 25: ...5KHz Standard ISO18000 2 Support card EM4100 EM4205 EM4305 EM4450 TK4100 T5567 T5577 Compatible HID 2 Output format Wiegand 26 34 bit M251022CR Display module with IC card reader Work frequency 13 56MHz Standard ISO 14443A Support card Mifare One S50 S70 etc Output format Wiegand 26 34 bit 4 7 Nameplate module No Functions ...

Страница 26: ...ous module 2 Connector for next module Labeling of the nameplate module can be printed by using the labelling tool of the ABB Welcome configuration software Pos 18 DinA4 Anl eitungen Onli ne Ueberschriften 1 Bedi enung 18 mod_1302613924165_15 docx 103365 1 1 ...

Страница 27: ... 103540 2 1 5 1 Pushbutton outdoor station Pos 20 DinA4 Anl eitungen Onli ne Ueberschriften 3 Bedi enel emente 20 mod_1323260220559_15 docx 111647 3 1 5 1 1 Addressing 1 Configure functions of the 1st 2nd pushbutton No Functions 1 3 OFF 4 OFF 2 Call apartment 01 3 Call apartment 02 4 Call apartment 03 3 4 DIP 1 2 3 1 2 3 4 001 002 003 ...

Страница 28: ... address of this outdoor station 3 Call apartment 01 4 Call apartment 02 No Functions 1 3 OFF 4 ON 2 Call the guard unit If there are multiple guard units in the same section all guard units will ring at the same time when a visitor presses the button call guard unit 3 Call apartment 01 4 Call apartment 02 3 4 DIP 1 2 1 2 3 4 001 002 3 4 DIP 1 2 1 2 3 4 001 002 Guard unit ...

Страница 29: ...ABB Welcome Operation 29 No Functions 1 3 ON 4 ON 2 Switch on lights 3 Call guard unit 4 Call apartment 01 3 4 DIP 1 1 2 3 4 001 Guard unit ...

Страница 30: ...t 01 3 Call apartment 02 4 Call apartment 03 5 Call apartment 04 No Functions 1 2 ON 2 Call apartment 01 3 Call apartment 02 4 Call apartment 03 5 Call apartment 04 6 Call apartment 05 7 Call apartment 06 2 ON 1 2 3 5 1 2 3 4 4 001 002 003 004 2 ON 1 3 5 9 7 2 4 8 6 2 4 6 8 1 3 5 7 001 001 002 003 004 005 006 007 008 ...

Страница 31: ...ng the language for the voice messages if the audio module has a speech synthesis function If the audio module with a speech synthesis function M251024A the local language can be set Set outdoor station address as 0 and hold the 1st button for 3s to play the voice message Click on this button to select the language After choosing the language hold this button to save and exit the setting 3 4 DIP 1...

Страница 32: ...ABB Welcome Operation 32 1 2 3 4 2 4 6 8 3 5 7 Single column Double column 1 1st button ...

Страница 33: ...inA4 Anl eitungen Onli ne Ueberschriften 3 Abschlusswiderstand 19 mod_1321958079906_15 docx 110083 3 1 Pos 72 DinA4 Anl eitungen Onli ne Inhalt KN X D oor Entr y Bedienung Abschl usswiderstand setzen 83220 AP xxx 19 mod_1310723392369_15 docx 107841 1 Apartment 01 A Apartment 02 B Apartment 03 C Apartment 04 A Apartment 05 B Apartment 06 C Outdoor station Left building Apartment 01 A Apartment 02 B...

Страница 34: ...aster card interface within 30s 4 Any card swiped by the reader during this time will be taken to be the new MASTER card A prompt Register master card successfully will appear on the screen If the card exists when you swipe it again the information will be deleted and a prompt Delete master card successfully will appear on the screen Only 1 master card can be registered Enter system setting using ...

Страница 35: ...rd Language Wiegand Output Swipe the MASTER card within 5s to move to next option Menu_________ Program Card Language Wiegand Output 5s over choose current option Menu_________05 Program Card Language Wiegand Output Swipe the MASTER card within 5s to move to next option Proximity Card 05 Register Card Delete Card Delete All Swipe the MASTER card enter the setting ...

Страница 36: ...tion Outdoor station system password 1 1 Gate Station system password 1 2 2 Modify system password system password 2 Enter new password 6 8 bits Enter the password again 3 Modify door open code system password 3 Enter new door open code 3 8 bits Enter the code again 4 Set the voice message If the audio module with the speech synthesis function M251024A is assembled the local language can be set sy...

Страница 37: ...ou have forgotten it The restoration of default factory settings does not delete the rest of the information programmed on the system such as user names and other settings 1 Disconnect the power supply 2 Reconnect the power 3 Hold the program button for 5s within 30s 4 A di will sound and the system password will be reset to the default 345678 ...

Страница 38: ...e implemented Function Command LED Enroll user Swipe admin card 1x Orange flash 1x Swipe card new user 1x Green Delete user Swipe admin card 2x Orange flash 2x Swipe card user x 1x Green Enroll new admin Swipe admin card 3x Orange flash 3x Swipe card new admin 1x Green Delete admin Swipe admin card 4x Orange flash 4x Swipe card admin x 1x Green Delete all users Swipe admin card 5x Orange flash qui...

Страница 39: ...ong press the program button for 5s within 60s Finish reset White Red green orange cycle Technical specifications for round pushbutton module with IC NFC Work frequency 13 56MHz Standard ISO 14443A Support card Mifare One S50 S70 etc Output format Wiegand 26 34 bit Support NFC device Mostly NFC mobile Not all tested is needed before using this function ...

Страница 40: ...on the door will be opened but a warning indication will be displayed on display module It is not necessary to play this warning Therefore validation needs to be switched off so that wrong indication on display module will not appear even though the card is not enrolled at this outdoor station 1 Swipe admin card to enter system setting Orange LED is on 2 Long press 1st button for 3s to switch vali...

Страница 41: ...ditional devices are not required for commissioning To the play store https play google com store apps details id com abb allegro3_nfcdooropener hl en 1 Download and install the ABB door opener app from Google Play Store 2 Turn on the NFC function of your device 3 Enter setting mode of your round pushbutton module 4 Start the app at your device 5 Set up your device as new user 6 Configure your per...

Страница 42: ...building number In standby mode a visitor can press the physical address corresponding to the residence from 001 to 250 For a complex building a visitor needs to press the building number 01 60 plus the physical address 001 250 or make a call in the gate station 2 Logic address Logic address is a code that a visitor can press to make a call The code must be assigned first and then associated with ...

Страница 43: ...o display resident names Use the buttons and to search for the desired residential station and press the button to make a call Also a visitor can enter the resident name using the keypad to make a call Resident names must be assigned first and then associated with the physical address system password system setting Contact Add User Names Physical Add 001 Logic Add 0101 Call Mode_______ Physical Ad...

Страница 44: ...mode If an indoor station works in the leave home mode a visitor can record a message for the resident after entering the following interface 30 s Guard Unit to Cancel 120 s Guard Unit to Cancel Accept the call 30 s Andy to Cancel 120 s Andy to Cancel Playing the message 001 s Recording to Cancel After a di sound visitor can record the message ...

Страница 45: ... indoor station will be intercepted by the guard unit and after the identity is confirmed the guard unit will forward the call to the indoor station Guard unit accepts the call Guard unit transfers the call to an indoor station 30 s Guard Unit to Cancel 120 s Guard Unit to Cancel Call from an outdoor station to an indoor station 120 s Andy to Cancel ...

Страница 46: ...ystem password Configurations Device Type Outdoor St Default Gate station system password Configurations Device Type Gate station 2 Set the call mode Make a call by a physical address or a logic code Set the call mode by Physical Address system password Configurations Call mode Physical Address Menu__________ Configurations Access Control Contact Device Type_____ Outdoor St Gate Station Device Typ...

Страница 47: ...l mode Logic Code 3 System password setting Modify the system password system password Configurations System code Modify Reset the system password system password Configurations System code Reset Call Mode_______ Physical Add Logic Add New Password Re enter Done Reset System Code to Confirm to Cancel Done ...

Страница 48: ...tions A total of 6 000 passwords can be stored Set the door open password ON OFF default 123456 system password Access Control Door open code Enable disable Modify the door open password system password Access control Door open code Modify Reset the door open password system password Access control Door open code Reset Door Open Code__ Disable Modify Reset Done New Password Re enter Done Reset Doo...

Страница 49: ...rds system password Contact Proximity card Delete All 4 Contact 3 000 names using a combination of 24 alphanumeric characters 1 Add Add the contact by user names system password Contact Add User Names Enter Card No 0123456 Or Swipe the Card Enter Card No 0123456 Or Done Swipe the Card Enter Card No 0123456 Or Swipe the Card Enter Card No 0123456 Or Done Swipe the Card Delete All Cards to Confirm t...

Страница 50: ...mes system password Contact Modify User Names Modify the resident names with the corresponding physical address Modify contact by logic address system password Contact Modify Logic add Modify the logic address and its corresponding physical address using the alphanumeric keypad 3 Delete Delete the contact by user names system password Contact Delete User Names Physical Add 001 Logic Add 0101 Alexa...

Страница 51: ...ystem password Contact Delete Logic add 4 Clear all system password Contact Clear all Clear all lists including resident names and logic address entries from this menu Alexander G Bodin K Christian G Enter Logic Add 0101 Delete All Names to Confirm to Cancel Done ...

Страница 52: ...dule with the speech synthesis function M251024A is assembled the speech synthesis function can be enabled or disabled Meanwhile the local language can be chosen too system password Settings Voice message If the audio module does not have a speech synthesis function this will be indicated when user enters the menu 4 Select language 2016 01 01 07 00 to Confirm Done 2nd Lock Open Time 1 10s 3s to Co...

Страница 53: ...tput digits system password Settings Wiegand Output 7 Set the related door lock when swiping the card system password Settings Choose Door Setting the lock that will be released when swiping the registered card 8 Reset Language_______ English Franç ais Italiano New Message ABB Welcome to Confirm to Cancel Done Wiegand Output__ 26 bit 34 bit Choose Door____ 1st Lock 2nd Lock ...

Страница 54: ...er information e g user names logic addresses and card information cannot be reset 9 Information system password Settings Information View the software information of each modules of the outdoor station Reset to Factory Default to Confirm to Cancel Done Audio module V1 07_131106 Card reader V0 10_131107 ...

Страница 55: ...y settings does not delete the other information programmed on the system such as user names and other settings 1 Disconnect the power supply 2 Reconnect the power 3 Hold the program button for 5s within 30s 4 A di will be sounded and the system password will be reset to the default 345678 Pos 67 DinA4 Anl eitungen Onli ne Ueberschriften 2 Rei nigung 19 mod_1310733980533_15 docx 107853 2 1 ...

Страница 56: ...e a call to a guard unit 5 6 3 System settings Users can enter the system settings by following these steps In settings press to confirm press to cancel The default system password is 345678 1 Set the device as an outdoor station or a gate station Outdoor station system password 1 1 Gate station system password 1 2 2 Modify the system password system password 2 Enter new password 6 8 bits Enter th...

Страница 57: ...the factory setting if you have forgotten it The restoration of default factory settings does not delete the other information programmed on the system such as user names and other settings 1 Disconnect the power supply 2 Reconnect the power 3 Hold the program button for 5s within 30s 4 A di will be sounded and the system password will be reset to the default 345678 Pos 21 DinA4 Anl eitungen Onli ...

Страница 58: ...llungen 18 mod_1302768847744_15 docx 103548 2 1 6 Advanced configuration Connect to the PC to configure the keypad or display Pos 75 Busch Jaeg er Neustr uktur Modul Struktur Online Dokumentati on Steuermodul e Onli ne D okumentation Fü r all e D okumente Seitenumbruch 9 mod_1268898668093_0 docx 52149 1 ...

Страница 59: ...05 1 Designation Value Operating temperature 40 70 Protection cover frame assembled IP 54 Power supply door opener Lock GND 18V 4A impulsive 250 mA holding Floating output door opener COM NC NO 30 V AC DC 1A Single wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Fine wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Bus voltage 20 30 V Pos 78 Busch Jaeg er Neustr uktur Modul Struktur Online Dokumentati on Steuermodul e...

Страница 60: ...4017_15 docx 103564 2 1 8 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g fire The minimum necessary expert knowledge and requirements fo...

Страница 61: ...system bus Avoid bridges between different cable types Use only two wires for the system bus in a four core or multi core cable When looping never install the incoming and outgoing bus inside the same cable Never install the internal and external bus inside the same cable The following installation situations must be avoided without fail Direct light Direct sunlight Extremely bright picture backgr...

Страница 62: ...5960458_15 docx 103424 2 1 8 3 Mounting Pos 85 1 DinA4 Anl eitungen Onli ne Inhalt KN X DoorEntr y 83220 AP xxx M ontag e M odul e Montage Montagedose 83220 AP xxx 19 mod_1323250406848_15 docx 111098 1 Dimension Prepare a pair of gloves to protect yourself from cutting Audio module Camera module Nameplate module Pushbutton module Keypad module Display and card reader module ...

Страница 63: ...ABB Welcome Mounting installation 63 Cover frame Flush mounted box ...

Страница 64: ...ABB Welcome Mounting installation 64 Components of the outdoor station Rain hood 1 3 2 4 ...

Страница 65: ...t the cover frame 1 Insert each module into the cover frame from behind until it clicks in place All modules can be inserted e g the camera module audio module push button module keypad module display and card reader module nameplate module 2 Pay special attention to the top to bottom orientation of each module Modules wiring ...

Страница 66: ...er one by one 2 Ensure that the audio module is connected next to the camera module The distance zones for the installation of the outdoor station When selecting the installation site ensure that the minimum distance to the right side is adhered to for the removal of the end strip ...

Страница 67: ...semble the frame into the flush mounted box 1 Hang the device in the installation box 2 Fasten the safety loop 3 Connect the wires into the enclosed clamp and plug the clamp onto the contact pins Fold the device and shut it until it audibly snaps in 4 Screw on the front of the device Four types of installation Option 1 Flush mounted only with a flush mounted box ...

Страница 68: ...ABB Welcome Mounting installation 68 Option 2 Flush mounted with a rain hood Option 3 Surface mounted with a rain hood Option 4 Cavity wall installation ...

Страница 69: ...ABB Welcome Mounting installation 69 ...

Страница 70: ...e enclosed mounting tool to remove the end strip 2 Remove the screw that is used to affix the cover frame 3 Push up and pull out the outdoor station on the bottom of the cover frame Dismount the modules 1 Dismount the module from one side of the module 2 Take out the modules ...

Страница 71: ...and write the user names on the label 2 Use a labelling sheet with appropriate software to correctly format and print the labels Adjust the angle of the camera Fig 1 Adjust the angle of the camera 1 Unscrew the camera 2 Adjust the angle of the camera in four directions up down right and left ...

Страница 72: ...ABB Welcome Mounting installation 72 3 Screw on the camera ...

Страница 73: ...ssemble the flush mounted boxes horizontally 3 Run the connection wires between the boxes The extension is useful for multi outdoor station connections Pos 94 Busch Jaeg er Neustr uktur Modul Struktur Online Dokumentati on Steuermodul e Onli ne D okumentation Fü r all e D okumente Seitenumbruch 9 mod_1268898668093_0 docx 52149 1 ...

Страница 74: ...ackcover We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein T...

Отзывы: