Audio outdoor station installation

Operating Audio indoor station
Control elements

Audio indoor station installation

Unit: mm

117

120

46

1

2

No.

Description

1

Handset

While a call is coming, pick up the handset to activate the commu-
nication within 30 seconds and hang up the handset to end the call.

2

Unlock button

2A Open the door by pressing this button at any time.
2B Auto-unlock: the door is released automatically after incoming 

call. To activate this function, long press this button for more 
than 10 seconds until the blue LED is on. The same operation 
will deactivate the funcition. 

3

Programmable button 

3A Programmable for additional function, e.g. call guard unit, 

intercom etc.

3B Default function of programmable button 1 is to release the 2nd 

lock on the default outdoor station. 

4

Blue LED

4A LED light blue = auto-unlock function is enabled.
4B LED flashes slowly = an incoming call.
4C LED flashes quickly = the system is busy.

5

Red LED

5A LED light red = mute function is enabled.
5B LED flashes slowly = a button is pressed.
5C LED flashes quickly = the door is open exceeding the set time (a 

sensor must be connected).

6

Three-position selector to adjust ringtone volume

1
2

1

3

2

4

5

6

Содержание W2153 BL

Страница 1: ... English Español ABB Welcome Quick Guide Audio Kit Audio Outdoor Station Teléfono con auricular y 3 pulsadores W2153 BL ...

Страница 2: ......

Страница 3: ... Content 004 009 010 015 English Español ...

Страница 4: ...mm 2 x 0 28 mm UTP 5 2 x Two pairs each core Ø 0 5 mm 8 x 0 2 mm A 650 610 410 230 640 B 200 190 130 70 200 English Wiring Lock connection Type A Type B Type C Distance a b a b 110 240 V ON ON M S RC Add 001 2 wire bus line 110 240 V A B a b Exit GND Lock COM NC NO a b Exit GND Lock COM NC NO PS a b Exit GND Lock COM NC NO PS ...

Страница 5: ...igure function of 1st 2nd push button 3 OFF 4 OFF call indoor station call indoor station 3 ON 4 OFF switch on lightings call indoor station 3 OFF 4 ON call guard unit call indoor station 3 ON 4 ON switch on lightings call guard unit 15 Adjust loudspeaker volume 16 Adjust door lock release time 1 10 seconds No Description 1 X100 X10 X1 Jumper to set the address of the indoor station Example settin...

Страница 6: ...is button for more than 10 seconds until the blue LED is on The same operation will deactivate the funcition 3 Programmable button 3A Programmable for additional function e g call guard unit intercom etc 3B Default function of programmable button 1 is to release the 2nd lock on the default outdoor station 4 Blue LED 4A LED light blue auto unlock function is enabled 4B LED flashes slowly an incomin...

Страница 7: ...tone function 3A Repeated ringtones indicate the function is enable default 3B Once ringtone indicates the function is disable 4 Hold Program 1 and Program 2 for 3 seconds to save the setting and exit the setting mode Step Description Blue LED Red LED 1 Pick up the handset hold Unlock for 3 seconds to enter the setting mode Flash times of red LED indicate the address of default outdoor station If ...

Страница 8: ...he address setting 4 Press Unlock repeatedly to set the tens digit in the sequency 0 1 2 3 4 5 6 7 8 9 0 The value is indicated by the LED flash times The value will be resetore to 0 when Program 2 is pressed during the setting 5 Press Program 1 repeatedly to set the units digit in the sequency 0 1 2 3 4 5 6 7 8 9 0 The value is indicated by the LED flash times The value will be resetore to 0 when...

Страница 9: ...P 5 2 x dos pares cada núcleo Ø 0 5 mm 8 x 0 2 mm A 650 610 410 230 640 B 200 190 130 70 200 Español Cableado Conexión de la cerradura Type A Type B Type C Distancia a b a b 110 240 V ON ON M S RC Añadir 001 Línea de bus de 2 cables 110 240 V A B a b Exit GND Lock COM NC NO a b Exit GND Lock COM NC NO PS a b Exit GND Lock COM NC NO PS ...

Страница 10: ...4 Configurar funciones de los pulsadores 1 º 2 º 3 APAGADO 4 APAGADO llamar a estación interior llamar a estación interior 3 ENCENDIDO 4 APAGADO encender iluminación llamar a la estación interior 3 APAGADO 4 OENCENDIDO llamar al puesto de guardia llamar a la estación interior 3 ENCENDIDO 4 ENCENDIDO encender iluminación llamar al puesto de guardia 15 Ajusta el volumen del altavoz 16 Ajustar el tie...

Страница 11: ...más de 10 segundos hasta que se encienda el LED azul La misma operación desactiva esta función 3 Botón programable 3A Programable para función adicional p ej llamar al puesto de guardia intercomunicador etc 3B La función predeterminada del botón programable 1 es abrir la 2 ª cerradura de la placa de calle predeterminada 4 LED azul 4A LED azul encendido función de apertura automática activada 4B LE...

Страница 12: ...ca que la función está activada predeterminado 3B Tono de llamada único indica que la función está desactivada 4 4Mantenga pulsados Program 1 y Program 2 durante 3 segundos para guardar la configuración y abandonar el modo de ajuste Paso Descripción LED azul LED rojo 1 Coja el auricular mantenga pulsado Unlock durante 3 segundos para acceder al modo de configuración El número de destellos del LED ...

Страница 13: ...rección 4 Pulse varias veces Unlock para establecer el dígito de decenas de la se cuencia 0 1 2 3 4 5 6 7 8 9 0 El valor lo indica el número de parpadeos del LED El valor volverá a 0 al pulsar Program 2 durante el ajuste 5 Pulse Program 1 varias veces para establecer el dígito de las unidades de la secuencia 1 2 2 4 5 6 7 8 9 0 El valor lo indica el número de parpadeos del LED El valor volverá a 0...

Страница 14: ...14 ABB WELCOME AUDIO KIT Note ...

Страница 15: ......

Страница 16: ... 18 20010 Vittuone MI Italy For Non EU conturies ABB Xiamen Smart Technology Co Ltd No 7 Fangshan South Road Xiang An Xiamen Fujian 361000 China www abb com 2TMU200000M0081100 Copyright 2020 ABB All rights reserved Specifications subject to change without notice ...

Отзывы: