Q U I C K G U I D E
5
Interface description
Audio module on the video aluminum outdoor station
No.
Description
1
Connector for camera module
2
Connector for device software update
3
Plug-in clamps(COM-NC-NO) for floating output, door opener (30
V AC/DC 1 A)
4
Plug-in clamps(Lock-GND) for door opener (18 V 4A impulsive, 250
mA holding)
5
Plug-in clamps(DC-GND) for additional power supply
6
Plug-in clamps(a-b) for Bus connection
7
Connector for induction loop module
8
Connector for next module
9
Connector for exit pushbutton
10
Connector for sensor to check the door status
11
Rotary switch to set the address of OS (1-9)
12
Set feedback tone of push button: ON/OFF
13
Configure push button as single column or double columns
(ON= double columns; OFF= single column)
14
Configure function of 1st / 2nd push button
3->OFF, 4->OFF=call indoor station/call indoor station;
3->ON, 4->OFF=switch on lightings/call indoor station;
3->OFF, 4->ON=call guard unit / call indoor station;
3->ON, 4->ON=switch on lightings / call guard unit.
15
Adjust loudspeaker volume
16
Adjust door lock release time, 1-10 seconds
No.
Description
1
X100 X10 X1
Jumper to set the address of the indoor station.
Example: setting address 024
2
Master /Slave function
Only one indoor station in each apartment must be set as “Master”
(Jumper should be set as ‘M/S on’). All additional indoor stations
in the same apartment must be set as “Slave” (Jumper should be
set as ‘M/S off’).
3
Terminal resistor
In video installations or mixed audio and video installations, the
Jumper must be set as ‘RC on’ on the last device of the line.
4
a b = Bus connection
5
a potential free contact, such as a doorbell pushbutton
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
024
1
2
4
3
Indoor station
hundreds digits
X100
0
5