Assembly and disassembly
2-12
Assembly instructions
2.4.3
Installation
2.4.3.1 Electrical
installation
It must be ensured in installation of the TC 2013
•
that the cables do not rest on sharp edges,
•
that the cables as far as possible are laid in a cable duct,
•
the of risk of tripping is minimised.
Before electrical installation work is performed on the TC 2013
•
disconnect the power supply to the control part,
•
turn off the main on/off switch,
•
safely turn off the air supply to the TC 2013,
•
keep the system pressureless.
2.4.3.2 Pneumatic
installation
The connection of compressed air takes place at the push-in fitting or the screw-in thread G 1/8"
at the filter regulator.
WARNING
Electrical installation must only be performed by qual-
ified personnel!
NOTICE
The attached electrical circuit diagram must be
observed in installation! (see Chapter 2.10 Electrical
circuit diagram)
The grounding actions performed must be checked by
measurements and recorded.
CAUTION
Installation of the pneumatics must only be performed
by qualified personnel!
The TC 2013 is to connected so that the valves are not
electrically live in an emergency stop.
NOTICE
The attached pneumatic diagram must be observed in
installation! (see Chapter 2.9 Pneumatic plan)
Содержание TSC 2013
Страница 1: ... ROBOTICS Assembly instructions Torch Service Center TSC 2013 ...
Страница 6: ...Contents 3HDA000057A8519 001 I 6 ...
Страница 10: ...1 4 3HDA000057A8519 001 Torch Service Center TSC 2013 Assembly instructions ...
Страница 56: ...Electrical circuit diagram 2 36 3HDA000057A8519 001 Torch cleaner TC 2013 Assembly instructions ...
Страница 78: ...Dimension sheet Gas nozzle 5 2 3HDA000057A8519 001 Appendix Assembly instructions ...
Страница 87: ......