- 24 -
000319BG
2 - Characteristics
E
fficiency curves
The equipment was designed in consideration of current energy conser-
vation standards, to avoid waste and unnecessary leakage.
Graphs of the
efficiency curves of all
models of inverter described in this
manual are shown below.
The
efficiency curves are linked to technical parameters that are continually being developed
and improved and should therefore be considered approximate.
TRIO-5.8-TL-OUTD
TRIO-5.8-TL-OUTD-S
Pout% (320Vdc) Eff. (320Vdc)
20
94.7
30
95.8
50
96.5
75
96.6
100
96.5
Pout% (620Vdc) Eff. (620Vdc)
20
97.0
30
97.5
50
98.0
75
98.0
100
97.7
Pout% (800Vdc) Eff. (800Vdc)
20
96.0
30
96.9
50
97.5
75
97.7
100
97.6
TRIO-7.5-TL-OUTD
TRIO-7.5-TL-OUTD-S
Pout% (320Vdc) Eff. (320Vdc)
20
94.7
30
95.7
50
96.5
75
96.7
100
96.6
Pout% (620Vdc) Eff. (620Vdc)
20
96.9
30
97.5
50
98.0
75
98.0
100
97.5
Pout% (800Vdc) Eff. (800Vdc)
20
95.2
30
96.4
50
97.2
75
97.5
100
97.5
90
91
92
93
94
95
96
97
98
99
100
Efficienc
y, %
% of Rated Output Power
320 Vdc
620 Vdc
800 Vdc
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Efficiency curves
90
91
92
93
94
95
96
97
98
99
100
Efficienc
y, %
% of Rated Output Power
320 Vdc
620 Vdc
800 Vdc
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Efficiency curves