- 106 -
000335BG
8 - Maintenance
P
utting the inverter out of service
Before proceeding to putting the inverter out of service, it is necessary to
disconnect it in order to remove the connections safely and without any
dangerous voltages.
Below is the procedure for putting the inverter out of service:
• Once the inverter has been disconnected, wait for it to di
-
scharge and proceed to opening the front cover by unscrewing
the 8 fixing screws
• Remove all the connections on the inverter.
• Unscrew and remove the 2 blocking screws
19
located on
the sides of the inverter
• Lift and remove the inverter by uncoupling it from the bracket
• Reclose the cover and tighten the 8 fixing screws