background image

 

 
2TLC172125M0201 Rev.F

 

12

 

 

8

 

Troubleshooting  

8.1

 

LED indications 

LED indication 

Probable cause 

Action 

Red 

Device pushed/opened 

Check status of the device. 

Bad connection between 
loops (A and/or B) and 
device terminals 

Check terminals and fasten them 
carefully. 

+24 VDC connected to 
DYNlink signal input 

Check if there is +24 VDC on 
DYNlink signal input. If yes, check 
cable connections or the unit 
before. 

No LED light 

Loss of power supply 

Check +24 VDC / 0 VDC power 
supply. 

Green (but no DYNlink 
output detected) 

Defective DYNlink signal 
input to unit 

Check the DYNlink input or the unit 
before. 

Weak lights  

Unit is defective 

Replace the unit. 

 

 

 

 

Содержание Tina 3A

Страница 1: ...2TLC172125M0201 Rev F ORIGINAL INSTRUCTIONS new abb com low voltage products safety products SAFETY PRODUCTS Tina 3A 3Aps Adapter unit Product Manual ...

Страница 2: ...use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life ...

Страница 3: ...s 5 3 Product description 6 4 Installation 7 4 1 Installation precautions 7 4 2 Testing safety functions 7 5 Connections 8 5 1 Connection examples 9 6 Functions 10 6 1 LED Indications 10 6 2 Information output signal attributes 10 7 Maintenance 11 7 1 Maintenance precautions 11 8 Troubleshooting 12 8 1 LED indications 12 9 Dimensions 13 10 Technical data 14 11 Declaration of conformity 16 ...

Страница 4: ...sumed that the reader of this document has knowledge of the following Basic knowledge of ABB safety products Knowledge of machine safety 1 4 Special notes Pay attention to special notes in the document Warning Risk of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Risk of damage to the equipmen...

Страница 5: ...tions standards and the Machinery directive Warning Failure to comply with instructions operation that is not in accordance with the use prescribed in the instructions improper installation or handling of the device can affect the safety of people and the plant Warning For installation and prescribed use of the product the special notes in the instructions must be carefully observed and the techni...

Страница 6: ...allows easy installation of the adapter unit within the physical enclosure of the safety device while keeping the status LED visible on the outside of the housing Tina 3A 3Aps is equipped with a LED for visual status information of the safety device and the DYNlink safety circuit Tina 3A is also equipped with a M12 5 pole connector for easy connection to the DYNlink safety circuit Tina 3Aps is ide...

Страница 7: ...e safety loop cables safety loop A and B shall be as short as possible max 300 mm as longer cables increase the risk for electrical interference Warning All safety functions shall be tested before starting up the system 4 2 Testing safety functions After each step the status of the input can be read on the monitoring device Steps for testing LED indication DYNlink signal output 1 Interrupt the DYN...

Страница 8: ...area and cable length in chapter Technical data General Caution All cable colors according to ABB standard cables Warning Information output signals shall never be used for safety purpose s Warning The connection cables are not monitored and shall therefore be installed within the same physical enclosure as the safety device to maintain the highest safety level fault exclusion refer to EN ISO 1384...

Страница 9: ...2TLC172125M0201 Rev F 9 5 1 Connection examples Tina 3A Caution All cable colors according to ABB standard cables Tina 3Aps Caution All cable colors according to ABB standard cables ...

Страница 10: ...te of the internal safety loop A B Safety loops A and B Information output One or both safety loops open Low Both safety loops closed High The delay for switching the information output signal Information output signal switch High Low Low High Delay 60 ms 10 ms Note If any of the safety loops are open longer than 70 ms the information output is set low for approximately 1 2 s If any of the safety ...

Страница 11: ... tested regularly at least once every year to confirm that all the safety functions are working properly EN 62061 2005 A1 2013 A2 2015 EN ISO 13849 1 2015 Warning In case of breakdown or damage to the product contact ABB Do not try to repair the product yourself since it may accidentally cause permanent damage to the product impairing the safety of the device which in turn could lead to serious in...

Страница 12: ... Check terminals and fasten them carefully 24 VDC connected to DYNlink signal input Check if there is 24 VDC on DYNlink signal input If yes check cable connections or the unit before No LED light Loss of power supply Check 24 VDC 0 VDC power supply Green but no DYNlink output detected Defective DYNlink signal input to unit Check the DYNlink input or the unit before Weak lights Unit is defective Re...

Страница 13: ...2TLC172125M0201 Rev F 13 9 Dimensions All dimensions are in mm Tina 3A Tina 3Aps ...

Страница 14: ...of equipment Operating voltage 24 VDC 15 25 Total current consumption Maximum 35 mARMS Note Total current consumption is the supply current when there is no information output current no current on Tina 3 Aps power output Valid over the operating voltage and ambient temperature range DYNlink signal DYNlink Input signal voltage Minimum 8 VRMS Maximum 15 VRMS DYNlink Output signal voltage Minimum 8 ...

Страница 15: ...al Tinned stranded copper Tightening torque M12 connector 0 6 Nm M20 nut 2 2 3 Nm Size L x W x H 56 x 27 x 24 mm Weight 30 g Color Black Directives Harmonized standards Conformity European Machinery Directive 2006 42 EC EN ISO 12100 2010 EN 62061 2005 Cor 2010 A1 2013 A2 2015 EN ISO 13849 1 2015 EN 60204 1 2018 IEC EN 61508 1 7 SIL3 PFHD 4 50 10 9 EN 62061 SIL3 EN ISO 13849 1 PL e category 4 Certi...

Страница 16: ...2TLC172125M0201 Rev F 16 11 Declaration of conformity EC Declaration of conformity ...

Страница 17: ...2TLC172125M0201 Rev F 17 UK Declaration of conformity ...

Отзывы: