Parameter
Specification
Insulation
PVC or other material that is serviceable
for outdoor use and UV-protected
Test voltage
1.5 kV
Strip length
11 mm (0.43 in)
12.19.6
Optical CAN cables between the power cabinet and the charge post
Parameter
Specification
Number of cores
2 fibre cores for installation
2 fibre cores as spare parts
Type
OM3 (multimode) prefabricated
Connector
B-FOC (ST
®
)
Diameter
13 to 21 mm (0.51 to 0.83 in)
Wave length
850 nm
Material
PCF or fiberglass
Loop bend radius
Minimum 64 mm (2.5 in)
Strip length
11 mm (0.43 in)
12.19.7
Cable for the tilt sensor control
Note: The tilt sensor control cables must be suitable for a 600 V
environment.
Parameter
Specification
Number of cores
2 x 2 twisted pair (4 core)
Diameter (inside)
0.75 to 2.5 mm² (1.5 to 4.9 kcmil)
Diameter (outside)
5 to 10 mm (0.20 to 0.39 in)
Conductor
Fine strand copper wire
Insulation
PVC or other material that is serviceable
for outdoor use and UV-protected
Minimum test
1.5 kV
Strip lenght
11 mm (0.43 in)
12.19.8
Ethernet cable
Parameter
Specification
Type
Shielded (tinned copper braid)
Number of (twisted) pairs
4 x 2
Core identification
Acc. to DIN 47100
Cross section
0.5 - 0.75 mm²
Diameter
5 - 10mm
Conductor
Fine strand copper wire
Technical data
9AKK107992A2254-EN | 005