8.4.2
Data cable
All data cables connected to the device must be shielded. Shielded RJ45 connectors shall be
interconnected with the copper braid of the Ethernet cable.
Functional description
Ethernet (S/FTP, CAT5e)
Number of cores
8
Number of (twisted) pairs
4 x 2
Cross section range
0.25 – 0.75 mm
2
Min – Max external diameter to fit through
gland
4 – 8 mm
Shielding
Yes (tinned copper braid)
Conductor
Fine strand copper wire
Insulation
PVC or other material that can be used outdoor
and are UV-protected
Characteristic impedance
100 Ω
Minimum Test Voltage [AC]
700 V
Ambient Temperature range
-40°C to 70°C
Core identification
TIA/EIA-568-B.1-2001 T568A
Bend radius
≥5x diameter
8.5
Electrical specification
Nominal voltage
24 VDC ±25%
Nominal current
Max. 3 A
Overvoltage category per EN 61131-2
II
Galvanic isolation
Yes
Inrush current Typ. 5 A, max. 50 A for <500 μs
Inrush current Typ. 5 A, max. 50 A for <500 μs
8.6
Dimensions
Dimensions (H x W x D) – without mounting
bracket
115 x 40 x 198
mm
Weight
1170 g