5.8.4
Connect the tilt sensors
Preliminary requirements
•
Installation engineer
•
Torque screw driver
•
Wire cutter
•
Wire stripper pliers
•
Crimp pliers
•
For the specifications of the wires and the strip length, refer to section
•
For the wiring diagram, refer to section
Procedure
1. Prepare the wires.
2. Loosen the screws of the terminal block.
3. Connect these wires. :
1. V+ wire from the external customer interface, to the terminal V+.
2. Ground wire from the external customer interface, to the terminal GND.
3. First contact wire from the external customer interface, to the terminal NC.
4. Second contact wire from the external customer interface, to the terminal
COM.
4. Tighten the screws to the correct torque. For the specifications, refer to
.
5.9
Prepare for commissioning
Preliminary requirements
•
Installation engineer
Danger:
Hazardous voltage
•
Do not commission the EVSE. Only a service engineer of the
manufacturer is qualified to commission the EVSE.
Installation
9AKK108467A6398-EN | 002