![ABB Terra 124 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/abb/terra-124/terra-124_installation-manual_1105012.webp)
Danger:
General risk
•
If you use the EVSE in any other way than described in the related
documents, you can cause death, injury and damage.
•
Use the EVSE only as intended.
2.3
Working principles
2.3.1
Terra 94, 124 and 184 CC and CJ
A
S
R
Q
T
U
V
N
O
X
X
G
G
G
G
G
G
F
K
K
L
L
O
N
B
D
E
C
H
J
I
H
I
J
W
P
M
1
1
2
A
AC input cable
B
Manual switch
C
EMC filter
D
AC contactor
E
Residual-current device and
breaker
F
Power module matrix
G
Power module
H
DC filter
I
DC contactor
J
DC fuse
K
Overcorrect protection device
L
Charge cable
M
Interlink contactor
N
Insulation management interface
O
Charge protocol interface
P
Surge-protection device
Q
Residual-current device
R
Heater
S
Auxiliary power supply
T
Cabinet controller board
U
Power bridge
V
Touchscreen
W
Cooling fan
X
LED for the illumination of the
exterior of the EVSE
1
CAN bus signal 1
2
CAN bus signal 2
•
Black and bold lines: power connection
•
Black and thin lines: auxiliary power connection
•
Green lines: CAN bus
•
Purple lines: control signal or monitoring signal
Description
12