background image

Insert media to start the archiving process automatically

• Select the Channel Source

• Set the Input Filter Type: Instantanteous or Max.

and Min. Values during the sample interval.

• Select the input type, linearizer, ranges and

tag name

• Select the Alarm type, set the alarm trip points,

the tag and the hysteresis.

• Set the Count Rate, Preset & Predetermined

Count values

Channel n.n

Channels 1.1 -  1.6

Set Up

Analog I/P

Totalizer

Alarm A

Alarm B

Time

Common

Chart

Digital

Bar

Process

• Set the Mains Rejection Frequency

• Select the Relay Source and the Relay

Polarity

• Select the Analog Output Source & Ranges
• Select the Digital Output Sources & Polarity

I/O Modules

Note.

Modules fitted are

detected automatically

A:Analog I/P

B:Relay

C:Hybrid

I/O Modules

<configuration filename>.cfg

Save as Current Configuration

Save Configuration

Cancel

Exit

<configuration filename>.cfg

Internal Storage

External Storage

Archive

• Set the 

Archive File Enables

 – i.e. the files to be archived

• Set the 

Filename Tag

• Set the 

New File Interval

(hourly, monthly or none)

Connection
Details

SM1000 – QUICK START GUIDE

Configuration

Operator 1

Operator 2
Operator 3
Operator 4

User 1

Use the up and down keys to select your password.
Confirm with Enter key

0000

User 1

Edit Current Configuration

Open Configuration

New Configuration

Cancel

Disable Recording in Configuration

Main

Configuration

Menu

QuickStart

Template

Summary

Channels 1.1 to 1.6

QSMilliAmp

4 to 20mA inputs,

0 to 100.0 units

QSTHC_C

or QSTHC_F

Thermocouple type K

0 to 1000

°

C or 0 to 1000

°

F

QSR TD_C

or QSRTD_F

Pt100 inputs

0 to 1000

°

C or 0 to 1000

°

F

Q S F l o w

4 to 20mA, 0 to 180 l/hr,

Totalizer enabled

QSDairy

Delayed High/Low Process Alarm

Engineering Range –10 to 90

°

C

Configuration File

Common

Group 1

Channels 1.1 -  1.6

Group 2

Channels 2.1 - 2.6

Functions

I/O Modules

Exit

Chart speed Sample Rate

On board storage

 

10 mm/h

60s

12 months

20 mm/h

30

s

  6 months

6

60 mm/h

10s

  2 months

Channels

120 mm/h

 

5s

30 days

Enabled

240 mm/h

 

2s

14 days

720 mm/h

 

1s

  6 days

Group 1

Recording

4

Set the Sample Rate

5

Select the Views Required
and the Operator Menu Choices

6

Set Up the Archive Files

7

Change the Channel Configurations

1

Make Connections
& Power-up the
Instrument

2

Select the Configuration Level
and a Quick Start Template

3

Set the Time and Date

8

Set Up I/O

9

Exit Configuration and Save Changes

10

Start Recording!

Note.

For detailed information on setting all

configuration parameters, refer to the SM1000 User
Guide, part number IM/SM1000.