Communication
26 Sensyflow
FMT700-P
42/14-42-EN
Pos: 15.9 /Kommunikation/Durchfluss/FMT700-P/Befehlsliste @ 33\mod_1253169204578_3101.doc @ 301763 @ 4
6.1.1.3 Command
list
Enter the command
XB
CR
to access the command list.
When a monitor is connected, the following text appears:
CLS
Command list
Command
Description
<XR>
Reset supply / evaluation unit
<XTT>
Transmits general information
<XB>
Transmits interface command list
<XF>
Transmits error table
<XS>
Constantly transmits flowrate in selected unit
<XH>
Stops <XS> output and enables interface
<XE>
Only one measured value is transmitted
<XA>
Transmits totalized mass / standard volume in g/l once the stop bit has been
set (externally triggered)
<XZ>
Measuring rate change for display and analog out
Example: <XZ0100
CR
>; <XZ0005
CR
> !!! 4-character cycle number must be
used
<XSR>
Requests the set SAMPLE RATE
<XU0>
Selects first unit: kg/h
<XU1>
Selects second unit: e.g., m
3
N/h
<XSW1>
Switches sensor 1 to supply / evaluation unit
<XSW2>
Switches sensor 2 to supply / evaluation unit
<X$>
Transmits length of individual strings
<XTR>
Transmits most recently measured temperature value.
If no transmitter is connected, E 11 appears on the display;
in the event of a Pt100 sensor break: E 12
<XT1>
Switches temperature measurement sensor 1, value transmitted via <XTR>
<XT2>
Switches temperature measurement sensor 2, value transmitted via <XTR>
Sensor / Transmitter = flowmeter sensor