background image

 

2TLC172249M0201, rev. B 

www.abb.com/jokabsafety 

2013-04-10  

Minimum safety distance 

When using interlocking guards without guard locking to safeguard a hazard zone, the minimum allowed safety 

distance between the guarded opening and the hazardous machine must be calculated. In order to ensure that the 

hazardous machine motion will be stopped before it can be reached, the minimum safety distance is calculated 

according to EN ISO 13855 (“Positioning of safeguards with respect to the approach speeds of parts of the human 
body”). 
The minimum safety distance is calculated according to the formula: 

S = (K x T) + C 

Where 

S

 = minimum safety distance (mm) 

K

 = approach speed of a human body; 1600 mm/s 

T

 = the total time from opening of the guard until the hazardous machine movement has stopped, i.e. including 

control system reaction times and other delays (s) 

C

 = a safety distance taken from Table 4 or Table 5 of EN ISO 13857:2008, if it is possible to push fingers or a 

hand through the opening towards the hazard before a stop signal is generated 

In some cases, T might be reduced by the opening time of the guard until the opening size permits access of the 

relevant parts of the body. Refer to EN ISO 13855 for further details and EN ISO 13857 for specified values. 

Note that the red model (Sense7) is obsolete. 

It is only the stainless steel model (Sense7Z) that is active.

Содержание Sense 7 Series

Страница 1: ...gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Original instructions Sense7 series Non contact coded safety switch Note that the red model Sense7 is obsolete It is only the stainless stee...

Страница 2: ...ion documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in comb...

Страница 3: ...ption 5 3 Connections 6 Connection 6 Cable configurations 6 Pin configurations 6 4 Installation and maintenance 7 Installation and maintenance 7 Maintenance 7 Minimum safety distance 8 5 Application e...

Страница 4: ...hat the reader of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of safety devices and safety locks Knowledge of machine safety Special notes Pay a...

Страница 5: ...comply with the instructions or standards especially when tampering with and or modifying the product any liability is excluded Function description The magnetic switch is small in size which makes i...

Страница 6: ...actuator present Cable configurations ACTUATOR RECEIVER 1 RECEIVER 2 POWER RED 24VDC BLUE 0VDC BLACK IN WHITE OUT YELLOW IN GREEN OUT ORANGE IN BROWN OUT NC Circult 1 NC Circuit 2 NO Circult Pin confi...

Страница 7: ...nated when the switch is closed and are extinguished when the switch is open 5 Check that the machine stops and cannot be re started when each switch is open Warning All the safety functions must be t...

Страница 8: ...ing to the formula S K x T C Where S minimum safety distance mm K approach speed of a human body 1600 mm s T the total time from opening of the guard until the hazardous machine movement has stopped i...

Страница 9: ...LC172249M0201 rev B 9 www abb com jokabsafety 2013 04 10 5 Application examples Application example Note that the red model Sense7 is obsolete It is only the stainless steel model Sense7Z that is acti...

Страница 10: ...2TLC172249M0201 rev B 10 www abb com jokabsafety 2013 04 10 Note that the red model Sense7 is obsolete It is only the stainless steel model Sense7Z that is active...

Страница 11: ...D Stainless Steel Sense7Z 2TLA050056R5120 5 m cable 2NC 1NO LED Stainless Steel Sense7Z 2TLA050056R6120 10 m cable 2NC 1NO LED Stainless Steel Sense7Z 2TLA050056R2120 250 mm cable with M12 2NC 1NO LED...

Страница 12: ...5 mm Switching Distance target to target Sao 10 mm close on Sar 20 mm open off Tolerance to misalignment 5 mm in any direction from 5 mm setting gap Switching frequency 1 0 Hz maximum Approach speed 2...

Страница 13: ...depending on system architecture EN 62061 Up to SIL3 depending on system architecture Safety data PFHD B10d Proof test interval life MTTFd 2 52 x 10 8 3 300 000 operations at 100 mA load 47 years 470...

Страница 14: ...safety 2013 04 10 8 EC Declaration of conformity ABB AB JOKAB SAFETY Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Note that the red model Sense7 is obsolete It is only the st...

Отзывы: