BUSCH-/ABB-SECURE@HOME
2CSM600727D0901
56/74
12.4.3
Alarms
Allows operating parameters such as type of sound, duration etc. of the alarm event siren to
be modified.
(*) Alarms include:
Away intrusion alarm, zone tampering alarm, Panic and System
tampering alarms
if the “system tampering” parameter is set to Yes.
Various parameters can be set for the various alarms. To configure the parameters of a
certain type of alarm, use the arrow keys to move to the corresponding one, select it and
press OK to salve.
The following parameters can be modified in the window that opens:
Alarm type / event
Sound
Frequency
Burst
LEDs
Type 1 alarms
Sweep /
Bitonal/
None
High
/Low
10s/ 30 s /
3 m
/ 9 m **
YES
/ NO
Alarm 2
Technological
Sweep
/
Bitonal/
None
High/Low
10s
/ 30 s
/ 3 m / 9 m
YES /
NO
External Activation
1 long beep
/
3 short beeps
/ none
1 long flash
/
3
short
/ NO
Deactivation
1 long beep
/
3 short
beeps / none
1 long flash
/ 3
short / NO
(**) To ensure compliance with EN 50131 1 and EN 50131 3 standards, siren activation time must be greater than
90 seconds and less than 15 minutes (without prejudice to local or national regulations to the contrary).
Factory settings are indicated in
bold
. To change a parameter, use the arrow keys to move to
it and press the OK key to confirm the selection.
WARNING!
The low frequency Sweep, high frequency Bitonal and low frequency Bitonal type
sounds do not comply with the EN
50131-1 standard.
12.4.4
Events
Allows the siren operating parameters to be modified for alarm system arming and
disarming events, using a procedure similar to the previous
Alarms.
REACTIONS Siren
1 Alarms (*)
2 Technological