BUSCH-/ABB-SECURE@HOME
2CSM600727D0901
19/74
3.4
Reset
If the alarm system cannot be armed due to potential inhibitions caused by technical alarms,
faults or tampering alarms affecting the detectors, e.g. jamming-supervision, the status of
the central unit or the individual zone should be reset. The function allows you to stop the
persistent fault report caused by failure to transmit the "all clear" signal (e.g. a technical
impulsive alarm such as a smoke alarm, flooding alarm, central unit battery, etc.).
A zone reset has to be carried out in order to reset sensor faults (Alarm memory and
Supervision).
The reset operation is recorded in the events log.
To reset the system or an individual zone, proceed as follows:
1.
Log in as a level 2 user
2.
Select Status and Events and press OK
3.
Select Status and press OK
4.
Select Alarm Reset: select System to reset the entire system, or the individual zone to
be reset. When the system is reset, all counters relating to multiple alarms will be set
to zero.
Status and Events
Status
1 Central unit
2 Zones and sensors
3 System devices
4 system restore
5 Sync queued