3.2.4. Updating revolution counters
43
3HAC 16578-1 Revision: E
© Copyri
ght
200
3-2007 ABB.
All rights reserved.
If the calibration marks seem to be wrong (even if the motor calibration data is correct), try
to rotate the axis one turn, update the revolution counter and check the calibration marks
again (try both directions, if needed).
6WHS6WRULQJWKHUHYROXWLRQFRXQWHUVHWWLQJZLWKWKH738
This section details the second step when updating the revolution counter; storing the
revolution counter setting with the TPU (RobotWare 4.0).
IRB 6600/6650 / others
Yes
Yes
IRB 6600ID/6650ID
Yes
No
IRB 6620
Yes
No
IRB 6660
Yes
Yes
IRB 7600
Yes
Yes
5RERWYDULDQW
$[LV
$[LV
$FWLRQ
1RWH
1. Press the button "Miscellaneous" then ENTER to select the service
window.
xx0100000194
2. Select
Calibration
from the
View
menu.
The Calibration window appears.
If there is more than one unit connected to the robot, they will be listed
in the window.
xx0100000201
&RQWLQXHG
&RQWLQXHVRQQH[WSDJH