Main groups
Submenus
Description
Parameters
Used to view the menu tree structure for the
protection relay's setting parameters
Language selection
Used to change the language
Logout
Used to end the session
The WHMI can be accessed locally and remotely.
• Locally by connecting the laptop to the protection relay
• Remotely over LAN/WAN
2.7
User authorization
The user management for the protection relay can be handled in two possible ways.
Only one user management way can be enabled in the protection relay at a time.
For more information, see the cyber security deployment guideline.
2.7.1
Local user account management
Four factory default user accounts (VIEWER, OPERATOR, ENGINEER and
ADMINISTRATOR) have been predefined for the LHMI and the WHMI, each with
different rights and default passwords. The roles for these user accounts are the
same as the username. Additional user accounts can be added for the protection
relay.
IED Users in PCM600 is used to manage the user accounts. Each protection relay
supports eight fixed roles and 50 user accounts belonging to any one of these roles.
Each user account can be mapped to a maximum of eight roles.
The factory default passwords can be changed with Administrator user rights or
by the users themselves. Relay user passwords can be changed using the LHMI, IED
Users in PCM600 or the WHMI. Only Administrator can create user accounts and
update the roles-to-rights mapping. Administrator can also reset the passwords of
the users.
User authorization is disabled by default for the LHMI and can be enabled with
the
Local override parameter via the menu path Configuration > Authorization >
Passwords. WHMI always requires authentication. Changes in user management
settings do not cause the protection relay to reboot. The changes are taken into use
immediately after committing the changed settings.
2.7.2
Central account management
The user accounts and roles can be created and authenticated centrally in a CAM
server. CAM needs to be activated in the protection relay from Account Management
in PCM600.
A CAM server can be an Active Directory (AD) server such as Windows AD. There can
also be a secondary or redundant CAM server configured which can act as a backup
CAM server if the primary CAM server is not accessible.
1MRS759142 F
REX640 overview
REX640
Technical Manual
55
Содержание RELION REX640
Страница 1: ... RELION PROTECTION AND CONTROL REX640 Technical Manual ...
Страница 2: ......
Страница 3: ...Document ID 1MRS759142 Issued 2023 02 07 Revision F Copyright 2023 ABB All rights reserved ...
Страница 167: ...Figure 62 Signal outputs in power supply module 1MRS759142 F Basic functions REX640 Technical Manual 167 ...
Страница 184: ...Figure 84 mA channels working as mA outputs Basic functions 1MRS759142 F 184 REX640 Technical Manual ...
Страница 1868: ...Figure 989 ANSI extremely inverse time characteristics General function block features 1MRS759142 F 1868 REX640 Technical Manual ...
Страница 1869: ...Figure 990 ANSI very inverse time characteristics 1MRS759142 F General function block features REX640 Technical Manual 1869 ...
Страница 1870: ...Figure 991 ANSI normal inverse time characteristics General function block features 1MRS759142 F 1870 REX640 Technical Manual ...
Страница 1874: ...Figure 995 ANSI long time inverse time characteristics General function block features 1MRS759142 F 1874 REX640 Technical Manual ...
Страница 1875: ...Figure 996 IEC normal inverse time characteristics 1MRS759142 F General function block features REX640 Technical Manual 1875 ...
Страница 1876: ...Figure 997 IEC very inverse time characteristics General function block features 1MRS759142 F 1876 REX640 Technical Manual ...
Страница 1877: ...Figure 998 IEC inverse time characteristics 1MRS759142 F General function block features REX640 Technical Manual 1877 ...
Страница 1878: ...Figure 999 IEC extremely inverse time characteristics General function block features 1MRS759142 F 1878 REX640 Technical Manual ...
Страница 1882: ...Figure 1002 RI type inverse time characteristics General function block features 1MRS759142 F 1882 REX640 Technical Manual ...
Страница 1885: ...Figure 1004 UK rectifier inverse time characteristic 1MRS759142 F General function block features REX640 Technical Manual 1885 ...
Страница 1959: ......