PCM600
Ethernet switch
Utility: IEC 60870-5-104
Industry: OPC
COM600S
Web HMI
ABB
MicroSCADA Pro/
System 800xA
Analog and binary horizontal
GOOSE communication
IEC 61850
PCM600
Ethernet switch
COM600S
Web HMI
Analog and binary horizontal
GOOSE communication
IEC 61850
GUID-4D002AA0-E35D-4D3F-A157-01F1A3044DDB V4 EN
Figure 7.
ABB power system example using Relion relays, COM600S and MicroSCADA Pro/System 800xA
6. Control
REV615 integrates functionality for the control of a circuit
breaker via the front panel HMI or by means of remote controls.
In addition to the circuit breaker control the relay features two
control blocks intended for motor-operated control of
disconnectors or circuit breaker truck and their position
indications.
The relay has one control block intended for motor-operated
control of one earthing switch control and its position
indication. Two physical binary inputs and two physical binary
outputs are needed in the relay for each controllable primary
device taken into use. The number of unused binary inputs and
binary outputs varies, depending on the chosen standard
configuration of the relay. Further, some standard
configurations offer optional hardware modules that increase
the number of available binary inputs and outputs.
If the amount of available binary inputs or outputs of the chosen
standard configuration is not sufficient, the standard
configuration can be modified to release some binary inputs or
outputs which have originally been configured for other
purposes, when applicable, or an external input or output
module, for example, RIO600 can be integrated to the relay.
The binary inputs and outputs of the external I/O module can be
used for the less time critical binary signals of the application.
The integration enables releasing of some initially reserved
binary inputs and outputs of the relay in the standard
configuration.
The suitability of the binary outputs of the relay which have been
selected for controlling of primary devices should be carefully
verified, for example the make and carry as well as the breaking
capacity. If the requirements for the control-circuit of the
primary device are not met, the use of external auxiliary relays
should be considered.
The optional large graphical LCD of the relay's HMI includes a
single-line diagram (SLD) with position indication for the
relevant primary devices. Interlocking schemes required by the
application are configured using the signal matrix or the
application configuration functionality of PCM600.
Capacitor Bank Protection and Control
1MRS757952 D
REV615
Product version: 5.0 FP1
ABB
11
Содержание RELION REV615
Страница 1: ... RELION 615 SERIES Capacitor Bank Protection and Control REV615 Product Guide ...
Страница 58: ...58 ...