3.14.2
Functions
CONDITION MONITORING
AND SUPERVISION
OR
AND
CONTROL AND INDICATION
1)
MEASUREMENT
FEEDER PROTECTION AND CONTROL RELAY
STANDARD
CONFIGURATION
PROTECTION
LOCAL HMI
Object
Ctrl
2)
Ind
3)
CB
DC
ES
1)
Check availability of binary inputs/outputs
from technical documentation
2)
Control and indication function for
primary object
3)
Status indication function for
primary object
R
L
Clear
ESC
I
O
Configuration
A
System
HMI
Time
Authorization
R
L
Clear
ESC
I
O
U12 0. 0 kV
P 0.00 kW
Q 0.00 kVAr
IL2 0 A
A
*
OR
REMARKS
Optional
function
No. of
instances
Alternative
function to be
defined when
ordering
Io/Uo
Calculated
value
3×
Reserves the 3I inputs for the
high-impedance based differential
purpose when this functionality is used
REF615
COMMUNICATION
Protocols:
IEC 61850-8-1/-9-2LE
Modbus
®
IEC 60870-5-103
DNP3
Interfaces:
Ethernet: TX (RJ45), FX (LC)
Serial:
Serial glass fiber (ST),
RS-485, RS-232
Redundant protocols:
HSR
PRP
RSTP
N
- I, U, Io, Uo, P, Q, E, pf, f
- Limit value supervision
- Load profile record
- RTD/mA measurement (optional)
- Symmetrical components
4
5
Analog interface types
1)
Current transformer
V
oltage transformer
1)
Conventional transformer inputs
ALSO AVAILABLE
- Disturbance and fault recorders
- Event log and recorded data
- High-Speed Output module (optional)
- Local/Remote push button on LHMI
- Self-supervision
- Time synchronization: IEEE 1588 v2,
SNTP, IRIG-B
- User management
- Web HMI
1
-
2
3
1
2
SYNC
25
O
→
I
79
2×
I2>
46
3Ith>F
49F
3I>>>
50P/51P
3×
ARC
50L/50NL
Master Trip
Lockout relay
94/86
Master Trip
Lockout relay
94/86
3×
2×
3I>>
→
67-2
3I>/Io>BF
51BF/51NBF
3I2f>
68
PQM3I
PQM3I
PQM3U
PQM3V
PQMU
PQMV
MCS 3I
MCS 3I
FUSEF
60
CBCM
CBCM
2×
TCS
TCM
OPTS
OPTM
2×
3I>
51P-1
3I>>
51P-2
I2/I1>
46PD
3I
3I
U
L1
U
L2
U
L3
U
12
U
12
Uo
3×
3U<
27
U2>
47O-
U1<
47U+
3×
3U>
59
3×
Uo>
59G
6×
f>/f<,
df/dt
81
U
L1
U
L2
U
L3
Uo
VS
78V
U<RT
27RT
3×
P>/Q>
32R/32O
Q>
→
, 3U<
32Q, 27
Io
PQUUB
PQVUB
Io
Io
2×
3I>
→
67-1
U
L1
U
L2
U
L3
3×
2xRTD
1xmA
18×
MAP
MAP
FLOC
21FL
SOTF
SOTF
dHi_A>
87A
dHi_B>
87B
dHi_C>
87C
*
*
*
MCS I_A
MCS I_A
MCS I_B
MCS I_B
MCS I_C
MCS I_C
Io>>>
50N/51N
Io>>
51N-2
2×
Io>
51N-1
PHIZ
HIZ
2×
Io>
→
67N-1
Io>>
→
67N-2
Io>IEF
→
67NIEF
3×
Yo>
→
21YN
3×
Po>
→
32N
Io>HA
51NHA
OR
OR
Io>
→Y
67YN
*
*
*
2×
2×
2×
GUID-33D8F0DD-5B76-40C1-8FAB-EF75271C1F88 V3 EN
Figure 561:
Functionality overview for standard configuration N
3.14.2.1
Default I/O connections
Connector pins for each input and output are presented in the IED physical
connections section.
1MRS756378 S
Section 3
REF615 standard configurations
REF615
355
Application Manual