IEC09000380-1-en.vsd
IEC09000380 V1 EN
Figure 30:
PCM600: Technical key editor
Using the
Technical Key Editor
the following selections are possible.
•
use the existing technical key in the IED
•
use the existing technical key defined for the IED object in PCM600 or
•
set a user defined technical key, which changes the technical key for both
the physical IED and IED object in PCM600.
Be sure to not use a technical key with more than 13 characters.
4.
Click
OK
to confirm the selection.
It is not possible to set a user defined name or select the
Technical key in IED
if
the value is the same as already given to another IED object in the PCM600
project. A dialog window opens if this is the case.
Section 4
1MRK 511 245-UUS -
Setting up a project
52
650 series ANSI
Engineering Manual