Figure 2.

Distribution automation system overview

Wireless Controller

1MRS757423 A

REC601/603
Product version: 1.0

 
 

ABB

5

Содержание REC603

Страница 1: ...Wireless Controller REC601 603 Product Guide ...

Страница 2: ...revision history 25 Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB Oy ABB Oy assumes no responsibility for any errors that may appear in this document Copyright 2011 ABB Oy All rights reserved Trademarks ABB is a registered trademark of ABB Group All other brand or product names mentioned in this document may be tr...

Страница 3: ...es the outage time in affected areas The areas directly adjacent to these affected areas would also show reduced outages and overall effects It also reduces the capital expenditures in the distribution network by limiting the replacement of legacy devices and contributes to more direct cost savings by facilitating preventative maintenance Wireless Controllers REC601 603 are also ideally suited to ...

Страница 4: ...re than three 3 disconnectors Overload protection of actuator motors Load current measured in the motor circuit Measurement of object transition time Energy limit based motor overload protection software fuse Always on two way communication based on GPRS via an M2M gateway Redundant IEC 60870 5 104 connections provide extra availability Communication monitoring and automatic connection re establis...

Страница 5: ...GUID B0E0CD80 91B5 4437 B5B0 0BB47638EBFD V1 EN Figure 2 Distribution automation system overview Wireless Controller 1MRS757423 A REC601 603 Product version 1 0 ABB 5 ...

Страница 6: ...trol Remote on off GUID 2EA84B83 9D8A 4B3F AC97 D99930FCB53B V1 EN Figure 3 Within the UEMC 50 the REC601 unit is used for the remote control of a disconnector The motor operating device is placed in the same UEMC 50 enclosure as the other equipment Wireless Controller 1MRS757423 A REC601 603 Product version 1 0 6 ABB ...

Страница 7: ... Remote on off Hall SF6 Alarm Serial port 24V DC mA sensor M M Battery charging Battery test Heater control GUID FA91F00E 70D2 404C 8F7A AEA72FB7F30B V1 EN Figure 4 A REC603 unit used for remote control of a Ring Main Unit Wireless Controller 1MRS757423 A REC601 603 Product version 1 0 ABB 7 ...

Страница 8: ...the dummy load Current and voltage measurements are taken for a defined period of time discharging time period Based on these measurements of the battery s current and voltage levels an assessment is made regarding the battery s condition and remaining operational capacity in Ah If the assessment shows that the battery has a significant depletion in capacity an IEC 60870 5 104 alarm event would th...

Страница 9: ...y inputs REC601 has 6 for monitoring and alarms and 7 binary outputs for disconnector control REC601 has 3 Both REC601 and REC603 devices each have 2 binary outputs and 2 analog inputs for battery control within the ranges of 0 30 V 0 10 A Further both the devices each have a binary output for over current motor control as well as an analog input for motor control within the range 0 15 A Additiona...

Страница 10: ...Blink GPRS is starting or transferring data Off GPRS is inactive AC and LINK LEDs AC Connected to AC power LINK IEC 60870 5 104 control link to SCADA is active Disconnector1 OPEN Open position indication CLOSE Close position indication LOCAL REMOTE Local remote control indication Grounding disconnector2 OPEN Open position indication CLOSE Close position indication 1 Applicable for disconnectors 1 ...

Страница 11: ...C237712F V1 EN Figure 6 Front panel 1 System status LEDs 2 X2 1 connector 3 X2 3 connector 4 X4 connector 5 AC and LINK LEDs 6 X3 connector 7 Disconnector status LEDs 8 Grounding disconnector status LEDs Wireless Controller 1MRS757423 A REC601 603 Product version 1 0 ABB 11 ...

Страница 12: ...7 Serial panel 1 Console serial port DIP switch selectable application or console port RS1 2 Power switch 3 Serial console switch RS1 4 Serial port 2 hardware configuration DIP switches 5 Serial port 2 6 Ethernet connector Wireless Controller 1MRS757423 A REC601 603 Product version 1 0 12 ABB ...

Страница 13: ...lowing users to develop solutions for their own applications with high data availability and reliability The devices are designed to withstand the operational requirements of most secondary substation environments and offer industrial quality connectivity devices for the IEC 60870 protocol family The IEC 60870 protocol family is a vendor independent communication standard for the power distributio...

Страница 14: ...urable to either console or data mode and supports only RS 232 while serial port 2 is configurable to multiple serial modes RS 232 422 485 Serial port connectors are 9 pin D sub male connectors More information is available in the Technical Data section of this product guide or technical manual available at www abb com substationautomation Wireless Controller 1MRS757423 A REC601 603 Product versio...

Страница 15: ...battery charger For 24 V sealed lead acid batteries Monitoring and protection Voltage load testing and deep discharge protection Table 4 Hardware Description Value Processor Environment Processor 32 bit RISC Memory 8 MB FLASH 32 MB SDRAM Other Sensor Temperature Internal clock Real time Approvals CE Environmental conditions Temperature ranges 40 70 C operation 40 85 C transport and storage Relativ...

Страница 16: ... masquerading NAT firewall Serial device connectivity Device server application IEC 60870 5 104 GW Simultaneous GPRS CSD and SMS SMS configuration and status reporting IEC 60870 5 104 and IEC 60870 5 101 IEC 60870 5 104 over TCP or UDP IEC 60870 5 101 FT 1 2 framing Local IEC 60870 5 101 polling ASDU replacer Packet compressor Table 6 Physical interfaces Description REC601 REC603 Binary Analog Bin...

Страница 17: ... Class Multi slot class 20 Mobile station class B Downlink speed Max 85 6 kbps Uplink speed Max 85 6 kbps Coding schemes CS1 4 Antenna connector FME 50 Ω Security Via encrypted VPN Serial Ports Serial 1 Console RS 232 IEC 60870 5 101 protocol support Serial 2 RS 232 422 485 selectable IEC 60870 5 101 protocol support Table 8 Communication protocols Description Value Protocols Via GPRS to and from ...

Страница 18: ... to line Voltage dips and short interruptions 0 1 cycle EN 61000 4 11 40 10 cycles 70 25 cycles Emission tests CISPR 22 EN 55022 Class B Conducted 0 15 0 50 MHz 66 dB µV quasi peak 56 dB µV average 0 5 5 MHz 56 dB µV quasi peak 46 dB µV average 5 30 MHz 60 dB µV quasi peak 50 dB µV average Radiated 30 230 Mhz 35 dB µV m quasi peak measured at 3 m distance 230 1000 MHz 42 dB µV m quasi peak measure...

Страница 19: ...owed and therefore deteriorated by nearby obstacles or enclosures Note also that large metallic surfaces racks or walls with metallic structures cabling concrete iron etc may degrade the antenna performance to a very high extent In this case it is highly recommended to use the optional external antenna with appropriate cable This allows for better positioning of the devices antennas and thus optim...

Страница 20: ...table RS232 422 485 A 11 Communication Protocols IEC 60870 5 101 IEC 60870 5 104 A 12 Wireless Communication Standards GPRS CSD GSM Data G 13 English 1 14 Additional components Stub antenna NTC sensor cable DIN rail mounting kit A Example code R E C 6 0 1 A 1 A A A G 1 A Your ordering code Digit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Code GUID 137E2DD5 4762 4A92 ABB7 705F552C1088 V1 EN Figure 9 REC601 o...

Страница 21: ...ctable RS232 422 485 A 11 Communication Protocols IEC 60870 5 101 IEC 60870 5 104 A 12 Wireless Communication Standards GPRS CSD GSM Data G 13 English 1 14 Additional components Stub antenna NTC sensor cable DIN rail mounting kit A Example code R E C 6 0 3 A 1 A A A G 1 A Your ordering code Digit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Code GUID 1BBA2F3F B538 48E0 ABE7 C141EDFE1154 V1 EN Figure 10 REC603...

Страница 22: ...ftersales relays fi abb com Table 12 Accessories Item Order number Hall effect current transducer 2RCA028227 Test load resistor 2RCA028171 Null modem cable 2RCA027558 Roof antenna with 150cm cable 2RCA028207 Table 13 Supporting product Item Order number M2M Gateway 2RCA028228 M2M Gateway Enterprise Edition 2RCA028229 11 Tools The devices can be configured using a graphical user interface via a Web...

Страница 23: ...GUID DABD1A6E 5A92 4286 9AB6 8C74E0A4ACDE V1 EN Figure 11 REC601 603 WebHMI Wireless Controller 1MRS757423 A REC601 603 Product version 1 0 ABB 23 ...

Страница 24: ...BD 9BE1 BD8F8D6EC3EF V1 EN Figure 12 X2 1 connector schematics OPENED 1 CLOSED 1 OPENED 2 CLOSED 3 LOC REM 1 LOC REM 2 CLOSE 1 OPEN 1 OPEN 2 CLOSE2 HEATER GUID 1087841A 5BD0 4724 B006 C7D415167D17 V1 EN Figure 13 X2 3 connector schematics Wireless Controller 1MRS757423 A REC601 603 Product version 1 0 24 ABB ...

Страница 25: ...nformation about the distribution automation product and service range You will find the latest relevant information on the above mentioned devices on the product pages The download area on the right hand side of the Web page contains the latest product documentation The selection tool on the Web page helps you find the documents by the document category and language The Features and Application t...