manualshive.com logo in svg
background image

3

4

EN

EN

2

EN

EN

In addition to what is explained below, the safety and installation information provided in the installation manual must be read and 

followed. The technical documentation and the interface and management software for the product are available at the website.

The device must be used in the manner described in the manual. If this is not the case the safety devices guaranteed by the inverter 

might be ineffective.

SOLAR INVERTERS

Quick Installation Guide

REACT2-BATT

— 

Labels and Symbols

Equipment Models and Components

Lifting and transport

List of supplied components

Safety precautions

The labels on the equipment have the Agency marking, main technical data and identification of the equipment and manufacturer

  

In the manual and/or in some cases on the equipment, the danger or hazard 

zones are indicated with signs, labels, symbols or icons.

Always refer to instruction man-

ual

General warning - Important 

safety information

Positive pole and negative pole 

of the input voltage (DC)

Temperature range

Hazardous voltage

Hot surfaces

Always use safety clothing and/

or personal safety devices

Point of connection for ground-

ing protection

The labels attached to the equipment must NOT be removed, dam-

aged, dirtied, hidden,etc...

Battery System provides a safe source of electrical energy when operated as intended and as designed.

Potentially hazardous circumstances such as excessive heat or electrolyte mist may occur under improper operating conditions, 

damage, misuse and/or abuse. The following safety precautions and the warning messages described in this Part must be ob-

served. 

HIGH VOLTAGE – ELECTRIC SHOCK HAZARD. Do NOT open any cover of REACT2-BATT

Organic Solvent Electrolyte

Cell components of Battery System contain organic solvent-based electrolyte. Breach of individual cells may allow some electrolyte 

to be released from the cell. Direct contact with the liquid electrolyte can cause skin irritation. 

If contact with the liquid electrolyte occurs, follow the suggestions below to minimize the chance of injury: 

•  Flush eyes immediately with cold running water for at least 15 minutes. 

•  Rinse skin immediately with water for at least 15 minutes. 

•  Remove clothing if soiled. 

•  Seek immediate medical attention.

Electrolyte Vent Product

Organic solvent electrolyte vent products are flammable. To avoid of flammable products, the following guidelines must be ob-

served:

•  Operate the Battery System under conditions only as specified

•  Keep sparks, flames and smoking materials away from the Battery

•  Do not incinerate, puncture or impact the Battery System.

•  Do not solder or weld to the Battery System.

HAZARD. The hazard warnings (set out below) are used to indicate risks or unsafe practices that CAN cause serious in-

jury or death.

•   DO NOT dismantle or disassemble any parts.

•   DO NOT set light to or heat.

•   DO NOT use or leave near a naked flame, boiler or heated places (beyond the temperature range indicated in the technical data). 

•   DO NOT wet with fresh or salt water. 

•  DO NOT create damawging impacts or drop.

•  DO NOT use for other equipment. 

•   DO NOT touch directly if there is a leak of electrolyte material. 

•   DO NOT touch if it shows any breaks in the cover where any parts under voltage are visible.

•   DO NOT use should a fault or any anomaly (such as in smell, heat, colour, smoke, shape or noise) be found.

WARNING. The warnings (set out below) are used to indicate risks or dangerous actions which COULD cause serious 

personal harm or damage to the product or property.

•   Do not use with other inverter models if not expressly indicated by ABB. 

•  Do not use if is leaking of electrolyte material.

•   Do not use if anomalies are present. Should the battery unit have a bad smell, changes in colouring, deformation or other anoma-

lous conditions during use (including charging and storage), do not use it.

CAUTION. The caution messages (set out below) are used to indicate risks or dangerous actions which could cause seri-

ous harm to people or damage to property.

•   Do not use or leave exposed to direct sunlight (or in a vehicle which is exposed to the sun). The REACT2-BATT could produce heat, 

smoke, breakages or flames. In addition, its performance might deteriorate and/or it might have a shorter lifespan.

Final installation of the equipment must not hinder access to any externally located disconnection devices.

The model of equipment to which this guide refers is REACT2-BATT.

The principal components of the REACT2-BATT are shown in the figure and described in the following table:

Transport and handling

The road transport of dangerous goods is regulated by the ADR international agreement.

The Battery Unit is identified in the ADR document by the number UN 3480 (LITHIUM-ION BATTERIES) in hazard CLASS 9. The bat-

tery unit, in its original packing, is compliant for road transport.

The ambient temperature allowed for transport is from -5°C to +40°C. The manufacturer guarantees the characteristics of the RE-

ACT2-BATT only if the aforementioned condition is respected.

•  Transport of new batteries 

The transport of Battery Units must comply with the general application of the ADR.  For any exemptions, please refer to para-

graphs 1.1.3.1 and 1.1.3.6 of the ADR document.

•  Transport of end-of-life batteries  

Besides complying with the general application of the ADR, Battery Units which are transported for disposal must comply with 

the following guidelines:

 

-

Be packed in accordance with packing instruction P909 of 4.1.4.1 (original package of REACT2-BATT)

 

-

The packages shall bear the following indication:  “LITHIUM BATTERIES FOR DISPOSAL”, in addition to other labels and indica-

tions provided for in the ADR.

For further details, please refer to the ADR document: “European Agreement concerning the International Carriage 

of Dangerous Goods by Road”, special regulation 377. 

Contact ABB for further details regarding the correct battery unit disposal procedures.

Storage of REACT-BATT

The storage period of the REACT2-BATT begins from the date, on which the product is produced by ABB (the production date is in-

dicated on the product label placed on the lateral surface of the chassis and expressed as week of production - Year of production). 

In order to guarantee the full operation of the system, REACT2-BATT shall be put into service within 6 months at most of the date of 

delivery by ABB to the recipient of the goods. 

In order to reduce risks during storage of the REACT2-BATT it must be considered that:
•  Do not stack more than 4 REACT2-BATT boxes.

•  Keep the boxes upright. Do not store upside down or on the sides. 

•  Storage temperature shall be in the range of -20 to +25°C (6 month storage time) or -20 to +45°C (3 month storage time).

•  Storage humidity shall be less than 80% RH non-condensing. 

•  Capacity degradation will occur depending on storage time, temperature, and humidity. 

•  To minimize capacity degradation, storing in a dry place with temperature less than 25°C.
For the rules on storing the battery, refer to the regulations in force in the country concerned. In addition to the regulations in force 

in the Country of interest, the following recommendations should be followed:
•  Store the Battery Unit in its original packing (including the pallet), in a dry, cool, well-ventilated environment and away from water.

•  Do not open/tamper with the original packing.

•  Do not crush/deform the packing. 

•  Equip the storage environment with appropriate PPE. 

•   Never leave the REACT2-BATT in places where these may be accidentally hit and damaged. 

•   Never leave the REACT2-BATT in areas with high fire risk or in high-temperature areas.

•   In the static position, the strapped batteries can be stacked up to a maximum of 4 units.  

•   Handling and loading onto means of transport is only allowed with a stack of maximum 2 units.

In case of damage or visible deformation of the cover contact ABB technical assistance service.

Lifting

Where indicated and/or where there is a provision, eyebolts or handles, which can be used as anchorage 

points, are inserted and/or can be inserted.

The ropes and means used for lifting must be suitable for bearing the weight of the equipment.

Equipment weight:

Model

Weight (kg)

Lifting points

REACT2-BATT

50

4 (suggested in case of 2 operators)

The number of required operators necessary to lift the equipment must be in accordance 

to local regulations relating lifting limits per operator

Unpacking and checking

Bear in mind that the packaging elements (cardboard, cellophane, staples, adhesive tape, straps, etc.) may 

cause cuts and/or injuries if not handled with care. They should be removed by suitable means and not left 

in the hands of individuals who are not responsible (e.g. children).

The packaging components must be disposed of in accordance with the regulations in force in the country 

of installation.

When you open the package, check that the equipment is undamaged and make sure all the components are 

present.

If any defect or damage is detected, please stop, contact the carrier and also promptly inform the ABB Service

Disposal of battery unit

ABB is responsible for the battery unit disposal. Contact the local ABB service for further details.

At the end of its life cycle, Battery Unit can be packed and transported by trained personnel in accordance with Chapter 1.3 ADR 

- See section “Transport of batteries at end of life”.

In case the original packing of the Battery Unit is no longer available, you may request a new one by contacting the ABB service.

Available components for REACT2-BATT

Quantity

Bracket for REACT2-BATT 

wall mounting

1

Cable lug for earth cable

2

REACT2-BATT power con-

nection cable

1

A4

1:1

1/1

Regulatory Label for MODEL REACT2-BATT

AA

Pantone

300 C

Process Yellow C

LABEL MATERIAL:

3M type 7331 (UL R/C, PGJI2)

INKS:

Refer to UL File MH16411

LABEL CONTENT:

Fixed as shown in the picture

SIZE:

125 mm (height) x 80 mm (width)

I

dc max (charge)

4.5 A

Contains Rechargeable Li-ion Battery

-  Refer to instruction manual for proper installation.
-  Do not remove the cover. No user serviceable parts inside.
-  Do not expose the unit to heating sources.
-  Do not expose the unit to direct solar irradiation.
- Do not install or operate the unit in potentially explosive

s.

atmosphere

WARNING!

www.abb.com/solar

BATTERY UNIT

REACT2-BATT

MODEL:

PROTECTIVE CLASS: I

Made in Italy

IP54

-20

55

(*)

to +

°C

-4

31

(*)

to +1

°F

XLP.V31xx.0AL

A.Statuti

G.Iannuzzi

A.Becattini

S.Bindi

30/07/2018
30/07/2018
30/07/2018
30/07/2018

V

dc max

575 V

W

hr

4.0 kWh

I

dc max (discharge)

5.6 A

V

dc operating range

170 - 575 V

(*): Out of 0 to +40 °C (+32 to +104 °F) temperature range, power derating occurs

All material used and finished product, must meet the requirements of the current RoHS

rective

i

Title

Issued

Modified

D

D

esign approved

Elec. Eng. approved
Mfg. approved

Size

Scale

Dim. in mm

Sheet

Drawing No.

Revision

© Copyright 2018 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.

Available components for REACT2-BATT

Quantity

REACT2-BATT signal con-

nection cable

1

 

M5 hex nuts , M5 flat 

washer and M5 serrated 

lock washer for protective 

earth cable installation

1+1+1

In additio

n to what 

is explain

ed in this

 guide, th

e safety a

nd installa

tion inform

ation pro

vided in th

e installat

ion manu

al must be

 read and

 followed

.

The techn

ical docu

mentation

 and the in

terface an

d manage

ment softw

are for th

e product

 are availa

ble at the

 website.

XXXXX

XXXXXX

XXXXX

XXX

XXXXX

XXXXXXX

XXXXXXX

ABB solar

 inverter

s

Technical documentation

1

a

Inverter/battery model

b

Main technical data

Main components
08

Battery communication connector COMM.[A]

23

Battery power connector POWER [B]

09

Battery power connector POWER [A]

24

REACT2-BATT external protective earth [B]

20

REACT2-BATT wall bracket

25

REACT2-BATT external protective earth [A]

21

REACT2-BATT

26

REACT2-BATT wall attachment point

22

Battery communication connector COMM.[B]

COMM.

[B]

POWER

[B]

COMM.

[A]

POWER

[A]

21

20

24

25

26

26

22

23

09

08

b

a

Отзывы: