Use of the safety function
Contents of this chapter
This chapter describes the use of the safety function with factory default settings.
Activating the safety function
Activation procedure:
1. Push the emergency stop button [S61] or a user-defined push button. The emergency
stop is activated. If the emergency stop button [S61] is pushed, the button locks in the
“ON” (open) position.
• ACS880-07CLC/07LC/17LC/37LC drives: the inverter unit control program has the
warning
Safe torque off
active
• ACS880 multidrives: the inverter unit control program has the warning
Emergency
stop
active
• the supply unit control program has the warning
Emergency stop
active
• the emergency stop reset button indicator light [S62] on the cabinet door is on.
If configured with parameter
31.22 STO indication run/stop
, an indication for Safe torque
off is shown when the drive STO is activated.
6