Technical data 137
Power factor (cos phi
1
)
adjustment range
0…1 capacitive or inductive depending on the dimensioning
The following graphs illustrate the equipment operation with the nominal AC
voltage and nominal ambient temperature. See
on page
.
Current
See section
Overvoltage category
(IEC 62109, IEC 60664-1)
3 (With F263, the category is 1.)
Harmonic distortion
THD current < 3% at nominal load
DC input connection data
Maximum DC power (
P
pv
)
See section
Maximum DC current
(
I
max(DC)
)
See section
Maximum DC voltage
(
U
max(DC)
)
Types -0100kW-A, -0250kW-A and -0315kW-B: 1000 V DC
Types -0500kW-A, -0630kW-B, -0875kW-B and -1000kW-C: 1100 V DC
Operational DC voltage
range,
U
mppt(DC)
Types -0100kW-A, -0250kW-A and -0500kW-A: 450…825 V DC
Types -0315kW-B, -0630kW-B and -0875kW-B: 525…825 V DC
Type -1000kW-C: 600…850 V DC
Voltage ripple
< 3%
Overvoltage category
(IEC 62109, IEC 60664-1)
2
P/P
N
(%)
90
80
70
60
50
40
30
20
10
0
-10
-20
-30
-40
-50
-60
-70
-80
10 20 30 40 50 60 70 80 90 100
0
100
-90
-100
Q
(%)
P/P
N
(%)
Q
(%)
90
80
70
60
50
40
30
20
10
0
-10
-20
-30
-40
-50
-60
-70
-80
10 20 30 40 50 60 70 80 90 100
0
100
-90
-100
Q
Reactive power in percentage of nominal active power
P/P
N
Relative active power
Types -0100kW-A and -0250kW-A
Types -0315kW-B, -0500kW-A, 0630kW-B, -0875kW-B,
-1000kW-C
10 000 -
P
act
2
Q
max =
Q
max
= 0.9 ·
10 000 -
P
act
2
Содержание PVS800-57-0100kW-A
Страница 1: ...ABB solar inverters Hardware manual PVS800 57 central inverters 100 to 1000 kW ...
Страница 4: ......
Страница 22: ...20 Safety instructions ...
Страница 64: ...62 Operation principle and hardware description ...
Страница 74: ...72 Mechanical installation ...
Страница 90: ...88 Electrical installation PE PE PE ...
Страница 124: ...122 Maintenance ...
Страница 152: ...150 Dimension drawings Frame R7i 3AUA0000083128 ...
Страница 153: ...Dimension drawings 151 AC output 3AUA0000083128 ...
Страница 154: ...152 Dimension drawings 3AUA0000083128 One DC input Four DC inputs ...
Страница 155: ...Dimension drawings 153 Frame R8i R8i 2 DC inputs option 2H382 or 4 DC inputs option 4H382 3AXD50000016935 ...
Страница 156: ...154 Dimension drawings R8i 8 DC inputs option 8H382 3AXD50000016935 ...
Страница 157: ...Dimension drawings 155 R8i AC output terminals 3AXD50000016935 ...
Страница 158: ...156 Dimension drawings R8i DC terminals of units with 2 DC inputs option 2H382 3AXD50000016935 ...
Страница 159: ...Dimension drawings 157 R8i DC terminals of units with 4 DC inputs option 4H382 3AXD50000016935 ...
Страница 160: ...158 Dimension drawings R8i DC terminals of units with 8 DC inputs option 8H382 3AXD50000016935 ...
Страница 162: ...160 Dimension drawings Frame 2 R8i 2 R8i 4 DC inputs option 4H382 or 5 DC inputs option 5H382 3AXD50000015007 ...
Страница 163: ...Dimension drawings 161 2 R8i 8 DC inputs option 8H382 or 10 DC inputs option 10H382 3AXD50000015007 ...
Страница 164: ...162 Dimension drawings 2 R8i 12 DC inputs option 12H382 or 15 DC inputs option 15H382 3AXD50000015007 ...
Страница 165: ...Dimension drawings 163 2 R8i AC output terminals 3AXD50000015007 ...
Страница 170: ...168 Dimension drawings Frame 3 R8i 3 R8i 8 DC inputs option 8H382 or 10 DC inputs option 10H382 3AXD50000015006 ...
Страница 171: ...Dimension drawings 169 3 R8i 12 DC inputs option 12H382 or 15 DC inputs option 15H382 3AXD50000015006 ...
Страница 172: ...170 Dimension drawings 3 R8i 16 DC inputs option 16H382 or 20 DC inputs option 20H382 3AXD50000015006 ...
Страница 173: ...Dimension drawings 171 3 R8i AC input terminals 3AXD50000015006 ...
Страница 178: ...176 Dimension drawings ...
Страница 179: ...Further information More information about ABB products for solar applications on the Internet www abb com solar ...