Operation Manual / Power2 340-H / Low-pressure stage
8 Troubleshooting / 8.4 Malfunctions when stopping
© Copyright 2022 ABB. All rights reserved.
HZTL4053_EN
Rev.F
March 2022
8.4
Malfunctions when stopping
Runout noises
Possible causes
Remedy
Low-pressure
or
high-pressure
stage
Pressure stage contaminated
Clean
Bearing damaged
Contact a Turbo Systems service sta-
tion
Rotor rubbing
Foreign object in the pressure stage
Table 34: Malfunctions when stopping – Runout noises
Runout time too short
Possible causes
Remedy
Low-pressure
or
high-pressure
stage
Pressure stage contaminated
Clean
Bearing damaged
Contact a Turbo Systems service sta-
tion
Rotor rubbing
Foreign object in the pressure stage
Table 35: Malfunctions when stopping – Runout time too short