![ABB PRO-33.0-TL Series Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/abb/pro-33-0-tl-series/pro-33-0-tl-series_service-manual_3045376033.webp)
Program features 33
Temperature control
The thermal model of the inverter controls the cooling of the inverter as well as protects it.
The thermal model controls the operation and speed of the cooling fans and limits the
output current, if needed. Overtemperature warning is indicated if the inverter temperature
exceeded the limit and current limitation is activated. If the temperature of the inverter
continues to increase, a fault is triggered and the inverter disconnects. The fault has to be
reset manually.
Diagnostics
: bit3 CB temperature, bit4 inverter temperature, bit5 filter temperature
Содержание PRO-33.0-TL Series
Страница 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Страница 4: ......
Страница 8: ...8 ...
Страница 12: ...12 Service menu ...
Страница 36: ...36 Program features ...
Страница 100: ...100 Parameters ...
Страница 112: ...112 Tools ...
Страница 121: ......
Страница 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...