![ABB Power2 850-M46 Скачать руководство пользователя страница 97](http://html.mh-extra.com/html/abb/power2-850-m46/power2-850-m46_operation-manual_2838038097.webp)
Operation Manual / Power2 850-M / 4.1 Low-pressure stage
4 Disassembly and assembly / 4.3 Removing the filter silencer
© Copyright 2019 ABB. All rights reserved.
HZTL4062_EN
Revision A
March 2019
4.3
Removing the filter silencer
u
Dismantle insulation as far as necessary.
u
If present: Disconnect supply line for compressor cleaning from filter silencer.
Fig. 4: Removing the filter silencer
1. Fit the swivel lifting eye (90231) to the silencer (81000). Attach the lifting gear to the
swivel lifting eye (90231) and loop through the eyelets at the rear of the filter silencer
(81000).
2. Loosen and remove nuts (72004). Remove washers (72003).
3. Remove and put down filter silencer.
4. Loosen and remove nuts (77022). Remove sleeves (77023).
Page
11
/
43