Tension Electronics PFEA113, User Manual
Section 3.12.3 Setting Object Type
3BSE029382R0101 Rev C
3-19
3.12.3.3 Setting Object Types for Segmented Roll
Object type
SegmentedRoll
can be used for up to 12 load cells that are connected to one, two or
three Tension Electronics PFEA113.
Each PFEA113 must be set up for:
•
one input (load cell connected to A)
•
two inputs (load cells connected to A and B)
•
three inputs (load cells connected to A, B and C) or
•
four inputs (load cells connected to A, B, C and D)
Figure 3-8. Setting Object Types for Segmented Roll
Use up and down keys to select type of object
[ZZ] from list
.
•
OneInput
•
TwoInputs
•
ThreeInputs
or
•
FourInputs
Segmented Roll Scale Factor (SRSF) is used to compensate the total measured tension and
present an estimate of total tension when not all rolls are supported by load cells in a segmented
roll application. For calculations of SRSF, refer to
.
Appendix A.3.1 Segmented Roll Scale
.
Figure 3-9. Segmented Roll Connected to One PFEA113
FastSetUp
WebTension
Presentation
-
Menu
SetNominal-
Load
ServiceMenu
ZeroSet
SetWrapGain
> 5 s
AO 1 - AO 6
Miscellaneous
Menu
System-
Definition
ObjectType
DO 1 - DO 4
AI 1 - AI 2
DI
SetObject
ZZ
AreYouSure
SetObject
[ZZ]
To
ObjectType
Setting Object Types for Segmented Roll
SetNominalLoad
A
B
PFEA113
Input
C
D
Three inputs
A
B
PFEA113
Input
C
D
Four inputs
Segmented Roll
(three or four load cells connected to one PFEA113)
A
B
A
B
C
D
C