7.3.2 Troubleshooting the FlexPendant
Procedure
The procedure below describes what to do if the FlexPendant does not work
correctly.
Note
Action
See
Operating manual - Omni-
Core
.
Try resetting the FlexPendant using the reset
button located next to the USB port.
1
Note
If protective gloves are used, these
must be compatible with touch-
screens when using the FlexPend-
ant.
If the FlexPendant is not responding or does not
operate correctly, see
necting the FlexPendant on page 356
.
2
Check the cable for connections and integrity.
3
Check the 24 V power supply.
4
Read the error event log message and follow any
instructions of references.
5
For more information on the FlexPendant, see
Operating manual - OmniCore
.
Product manual - OmniCore V400XT
367
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
7 Troubleshooting
7.3.2 Troubleshooting the FlexPendant