1.3.2 About emergency stop
The emergency stop
The purpose of the emergency stop function is to avert actual or impending
emergency situations arising from the behavior of persons or from an unexpected
hazardous event.
The emergency stop function is to be initiated by a single human action.
The emergency stop function is a complementary protective measure and shall
not be applied as a substitute for safeguarding measures and other functions or
safety functions.
The effect of an activated emergency stop device is sustained until the actuator
of the emergency stop device has been disengaged. This disengagement is only
possible by an intentional human action on the device where the command has
been initiated. The disengagement of the emergency stop device shall not restart
the machinery but only permit restarting.
Note
The emergency stop device on the FlexPendant is operational when the robot
is powered. Indicators to be used to verify that the robot is powered are the main
switch on the cabinet or the LED indicator on the cabinet when robot is in Motors
On Mode.
Recover from emergency stop
1 Inspect the machinery in order to detect the reason for the emergency stop
device actuation.
2 Locate and disengage the emergency stop device or devices that initiated
the emergency stop function.
22
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
1 Safety
1.3.2 About emergency stop
Содержание OmniCore V250XT
Страница 1: ...ROBOTICS Product manual OmniCore V250XT ...
Страница 2: ...Trace back information Workspace 22A version a10 Checked in 2022 03 02 Skribenta version 5 4 005 ...
Страница 34: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 174: ...This page is intentionally left blank ...
Страница 410: ...This page is intentionally left blank ...
Страница 418: ...This page is intentionally left blank ...
Страница 454: ......
Страница 455: ......