10.6 Reset user data
Overview
We recommend to perform a reset user data:
•
when you want to reset the RAPID in the system.
•
when you want to restore the system to its original state by resetting RAPID
and system parameters.
•
when you want to remove the user configured safety settings and load the
default safety settings.
Procedure
Use the following procedure to reset the system settings:
1 On the start screen, tap
Settings
, and then
Backup & Recovery
.
2 On the left sidebar tap
Reset user data
.
3 Select one of the following reset data options:
•
Reset RAPID
: To reset the RAPID data of the loaded system.
•
Reset RAPID and System Parameters
: To restore the system to its
original state by resetting the RAPID and system parameters.
•
Reset safety setting
: To remove the user configured safety settings
and load the default safety settings.
4 Tap
Reset
.
A confirmation message is displayed.
5 Tap
OK
.
The controller is restarted and the system is updated according to the selected
reset data settings.
226
Operating manual - OmniCore
3HAC065036-001 Revision: E
© Copyright 20192020 ABB. All rights reserved.
10 Install, update, restart, and other configuration
10.6 Reset user data
Содержание OmniCore S Series
Страница 1: ...ROBOTICS Operating manual OmniCore ...
Страница 2: ...Trace back information Workspace RW 7 1 version a5 Checked in 2020 10 25 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 22: ...This page is intentionally left blank ...
Страница 54: ...This page is intentionally left blank ...
Страница 60: ...This page is intentionally left blank ...
Страница 64: ...This page is intentionally left blank ...
Страница 208: ...This page is intentionally left blank ...
Страница 234: ......
Страница 235: ......