Note
Action
xx2200001330
Remove the cover plate on the back of the
balancing device.
DANGER
DO NOT remove any other screws than the
rear cover attachment screws.
2
Hydraulic press equipment, balancing
device: 3HAC074411-001
Unload the balancing device with the press
equipment, to make the piston rod and front
ear adjustable when pulling the shaft out.
3
User instructions are enclosed with the
tool.
xx0900000813
Go to the user instructions enclosed with
the press tool.
DANGER
Handling the tool incorrectly will cause
serious injury.
Read and follow enclosed user instructions
for the tool.
Attaching lifting accessory to the balancing device
Note
Action
CAUTION
The weight of the balancing device (exclud-
ing cradle) is 140 kg
All lifting accessories used must be sized
accordingly.
1
Continues on next page
Product manual - IRB 6740
189
3HAC085701-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the axis-1 cassette sealing
Continued