NIBA-01 Installation and Start-up Guide
5-1
Chapter 5 – Programming
Overview
This chapter gives information on configuring the drive and the
InterBus-S system for communication through the NIBA-01 Module. It
is assumed that the NIBA-01 has been mechanically and electrically
installed according to the instructions given in Chapters 3 and 4.
Drive Configuration
The detailed procedure of activating the module for communication
with the drive is dependent on drive type. (Normally, a drive parameter
must be adjusted to activate the communication. See the drive
documentation.)
As communication between the drive and the NIBA-01 is established,
the configuration parameters of the module become available at the
drive. These parameters – shown below in Table 5-1 – must be
checked first and adjusted if necessary. The alternative selections for
these parameters are discussed in more detail below the table. (Note
that the new settings take effect only when the module is powered up
for the next time.)
Note: The groupings, numberings, and adjustment procedures of
parameters vary. Refer to the drive documentation.
Table 5-1 NIBA-01 configuration parameters.
MODULE TYPE
This parameter shows the module type as detected by the drive. The
value cannot be adjusted by the user. (If this parameter is undefined,
the communication between the drive and the module has not been
established.)
Fieldbus
Par. No.
Name
Alternative
Settings
Default
Setting
Note
1
MODULE TYPE
NIBA-01 Vx.x
Not adjustable
2
COMM. MODE
PCP; IO
PCP
3
IB TIME-OUT
0 to 255
30
10
~
1 s
(0 = disabled)