2101510 Rev. AG
Page 3–63
The AC/DC power supply may be approved for classified
hazardous locations or potentially explosive atmospheres.
Verify the rating listed on the unit tag and install per the
referenced control drawing. Be sure to follow the requirements
of national and local codes when installing the power supply.
Installation must be performed by person(s) qualified for the
type and area of installation, according to national and local
codes.
3.31.1 Customer Supplied Materials
•
Plastic cable ties
•
AC wiring. Please refer to the cable recommendation chart in Chapter 1 (see
Table 2–5 AC Power Supply System Maximum Cable Lengths
•
Explosion-proof conduit with fittings and poured seals or approved explosion-
proof/flame-proof flexible cable with fittings according to the requirements of
the national and local codes.
Figure 3-66 Explosion-Proof AC Power Supply Top/Front Dimensions
9.63
9.12
10.67
10.12
10-24 GROUND LUG
7.37
2X 3/4 CONDUIT ACCESS HOLE