Devices 73
In any other case the button is disabled.
If the cause of the fault has been handled, you can reset the fault by clicking this
button. If a fault condition is active or a device has a permanent fault, the fault cannot
be reset via interferes.
•
Remove
button
The button is enabled when the associated drive has been disconnected from the
NETA-21. Use the button to permanently delete the drive from the drive list of a device
interface, for example, when the configuration of the system has changed.
The button is disabled when the drive has been reconnected to the NETA-21.
Parameter browser
Every device has one or more parameter browser tabs that list the parameter groups and
parameters of the device. You can mark favorite parameters with yellow and blue stars.
Parameters marked with a yellow star are shown in the
Favorite parameters
portlet on
the device front page. Parameters marked with a blue star are shown in the
Favorite
parameters
portlet on the
My frontpage
tab.
The toolbar of the
Parameter browser
tab contains the following components:
•
Filter parameters…
is a text box for finding parameters from the parameter list. The
parameter list is updated automatically when you type search criteria to this box.
•
Parameter status
is a check box for showing or hiding the parameter status bar of the
parameter view at the bottom of the window. The status bar is visible by default.
•
Refresh values
button updates the parameter values visible in the parameter list.
When the view is updated, the refresh button is disabled and the icon spins to indicate
that the refreshing is in progress.
The NETA-21 has a cached list of parameter groups and parameter names. The
Refresh values
button does not necessarily update all group names on the list, since
that would take too much time. Some of the parameter data will be updated after a
delay when you start browsing into the parameter groups. If it is uncertain that the
parameter list is up to date or if there are strange access errors when you try to open
parameter lists, the errors can be solved by reloading all device-specific data. To
Содержание NETA-21
Страница 2: ......
Страница 4: ......
Страница 18: ...18 Introduction to the manual ...
Страница 32: ...32 Electrical installation ...
Страница 42: ...42 Start up ...
Страница 50: ...50 Program features ...
Страница 56: ...56 Front page ...
Страница 68: ...68 Users ...
Страница 114: ...114 Networks ...
Страница 120: ...120 Events a single page the toolbar at the bottom of the Event tab can be used for changing pages ...
Страница 150: ...150 Reporting ...
Страница 172: ...172 Security ...
Страница 176: ...176 Memory card ...
Страница 184: ...184 Frequently asked questions ...
Страница 190: ...190 Diagnostics and troubleshooting ...
Страница 194: ...194 Technical data ...