Use suitable personal protective clothing.
•
Use only suitable tools and measuring devices.
•
Check the type supply network (TN system, IT system, TT system)
to secure the following power supply conditions (classic connection
to the ground, protective grounding, necessary additional
measures, etc.).
Pos : 82 /DinA4 - Anl eitungen Onli ne/I nhalt/ KN X/D oor Entr y/Mont age/M ont agehinweise - Allgemein @ 19\ mod_1310563670478_15. doc x @ 107743 @ 2 @ 1
8.2
General installation instructions
•
Terminate all branches of the wiring system via a connected bus device (e.g.,
indoor station, outdoor station, system device).
•
Do not install the system controller directly next to the bell transformer and other
power supplies (to avoid interference).
•
Do not install the wires of the system bus together with 100-240 V wires.
•
Do not use common cables for the connecting wires of the door openers and wires
of the system bus.
•
Avoid bridges between different cable types.
•
Use only two wires for the system bus in a four-core or multi-core cable.
•
When looping, never install the incoming and outgoing bus inside the same cable.
•
Never install the internal and external bus inside the same cable.
Pos : 83 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Steuermodul e - Onli ne-D okument ation (--> F ür all e D okument e <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\ mod_1268898668093_0.doc x @ 52149 @ @ 1
Содержание M25102xC Series
Страница 9: ...ABB Welcome Terminal description 9 4 1 1 Lock connected with terminals 3 4 ...
Страница 10: ...ABB Welcome Terminal description 10 4 2 Camera module Fig 3 Terminal description ...
Страница 13: ...ABB Welcome Terminal description 13 ...
Страница 15: ...ABB Welcome Terminal description 15 ...
Страница 59: ...ABB Welcome Mounting Installation 59 Cover frame ...
Страница 60: ...ABB Welcome Mounting Installation 60 Flush mounted box ...
Страница 61: ...ABB Welcome Mounting Installation 61 Rain hood ...