ABB-Welcome
|
— 33 —
6.2
General installation instructions
•
Terminate all branches of the wiring system via a connected bus device (e.g.,
indoor station, outdoor station, system device).
•
Do not install the system controller directly next to the bell transformer and other
power supplies (to avoid interference).
•
Do not install the wires of the system bus together with 100-240 V wires.
•
Do not use common cables for the connecting wires of the door openers and wires
of the system bus.
•
Avoid bridges between different cable types.
•
Use only two wires for the system bus in a four-core or multi-core cable.
•
When looping, never install the incoming and outgoing bus inside the same cable.
•
Never install the internal and external bus inside the same cable .
Pos : 83 /Busc h-J aeg er (Neustr ukt ur)/Modul- Struktur /O nline-Dokument ati on/Steuermodul e - Onli ne-D okument ation (--> F ür all e D okument e <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\ mod_1268898668093_0.doc x @ 52149 @ @ 1