![ABB LST400 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/abb/lst400/lst400_operating-instructions-manual_5422025.webp)
L ST4 0 0 |
U LT R A S O N I C L E V EL T R A N SM I T T ER
| O I/L S T4 0 0 - EN R E V. E
25
Fifo (first in first out) pump cycling
Security code
5159
Mode
LEVEL
Empty distance
16.5 ft / 5.00 m
Span
14.85 ft / 4.50 m
Blanking
1.63 ft / 0.50 m
Rate of change
3.28 ft/min / 1.00 m/min
Setup relays
YES
Relay 1
HI
Relay 1 set
4.95 ft / 1.50 m
Relay 1 reset
3.28 ft / 1.00 m
Pump cycling
FIFO
Relay 2
HI
Relay 2 set
11.55 ft / 3.50 m
Relay 2 reset
8.20 / 2.50 m
Pump cycling
FIFO
Relay 3
HI
Relay 3 set
13.2 ft / 4.00 m
Relay 3 reset
9.84 ft / 3.00 m
Pump cycling
FIFO
Empty distance
16.5 ft / 5.00 m
2.46 ft / 0.75 m
Blanking distance 1.63 ft / 0.50 m
Span 14.85 ft / 4.50 m
NOTICE
Set the relay set and reset point further apart to avoid the
relays from chattering.
The following will occur in the FIFO pump cycling routine:
Relay
Status
Time on in hrs
Sequence 1 Level 4.27 ft
Relay 1
OFF
0
Relay 2
OFF
0
Relay 3
OFF
0
Sequence 2 Level 7.22 ft
Relay 1
ON
1
Relay 2
OFF
0
Relay 3
OFF
0
Sequence 3 Level 11.81 ft
Relay 1
ON
2
Relay 2
ON
1
Relay 3
OFF
0
Sequence 4 Level 14.11 ft
Relay 1
ON
3
Relay 2
ON
2
Relay 3
ON
1
Sequence 5 Level 9.19 ft
Relay 1
OFF
4
Relay 2
ON
3
Relay 3
ON
2
Relay
Status
Time on in hrs
Sequence 6 Level 7.22 ft
Relay 1
OFF
4
Relay 2
OFF
4
Relay 3
ON
3
Sequence 7 Level 2.63 ft
Relay 1
OFF
4
Relay 2
OFF
4
Relay 3
OFF
4
Sequence 8 Level 5.91 ft
Relay 1
ON
5
Relay 2
OFF
4
Relay 3
OFF
4
Sequence 9 Level 2.63 ft
Relay 1
OFF
6
Relay 2
OFF
4
Relay 3
OFF
4
Sequence 10 Level 5.91 ft
Relay 1
OFF
6
Relay 2
ON
5
Relay 3
OFF
4