L ST4 0 0 |
U LT R A S O N I C L E V EL T R A N SM I T T ER
| O I/L S T4 0 0 - EN R E V. E
17
Run mode screen in distance/level mode
Dist. 6.00 ft
mA Output:
7.20mA
Instant:
6.00 ft
Temperature: 20°C
Percentage:
20.00%
1
Graphical representation
of percentage fill.
2
Instantaneous distance
3
Temperature of transducer
5
mA Output
4
Percentage fill
6
Distance /
Level
Measurement
1
The graphical representation of the percentage fill of the
application.
2
The instantaneous distance that the instrument is
measuring at that specific time. Please note that this value can
change on each pulse.
3
The temperature, which is being measured at the
transducer, if temperature compensation has been enabled.
4
The value of percentage fill of the instrument.
5
The mA output of the instrument.
6
The average Distance/Level value which is calculated.
The relay state screen
Pressing
ENTER
while in run mode to get the RELAY STATE SCREEN.
Relay
State
Hour
Cycles
REL 1:
OFF
LO
0
2
REL 2:
ON
HI
1
2
REL 3:
ON
HI
3
5
REL 4:
OFF
LO
0
0
REL 5:
INACTIVE
1
Description of column
2
Number of cycles
3
Hours relay has been on
4
Relay state
5
Relay number
1
Relay state headings.
2
The number of cycles each relay has been through.
3
The number of hours each relay has been on.
4
The state at which the relay is at ON, OFF, HI, LO and CO-Counter.
5
The relay indication number.