6.3 Type PROFINET Device
6.3.1 PROFINET Station Name
Parent
PROFINET Station Name
belongs to the type
PROFINET Device
, in the topic
I/O
System
.
Cfg name
StationName
Description
PROFINET Station Name
specifies the PROFINET station name on the network of
the external I/O device.
Usage
The parameter
PROFINET Station Name
is used to identify a PROFINET device
on the network. The name must be unique on the network.
Prerequisites
The option
PROFINET Controller/Device
or
PROFINET Device
must be installed.
Default value
The default value is an empty string.
Allowed values
The station name follows the PROFINET naming convention for IO devices.
Note
It is possible to set the PROFINET station name of a device and it does not follow
the naming restriction as the CFG name, which still has restrictions of a RAPID
Identifier.
56
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
6 System parameters
6.3.1 PROFINET Station Name