5.4.3 Installation locations for the calibration tools
Location of fixed calibration items
This section shows how the robot is equipped with items for installation of
calibration tools for Axis Calibration (fixed calibration pins and/or bushings).
Installed calibration tools are not shown.
A fixed calibration pin and a bushing for the movable calibration tool are located
on each axis as follows.
xx1500003256
The fixed calibration pin for axis 1 is installed on a removable tower. The tower will
need to be removed if electronic position switches are fitted to the robot. Keep the
tower in a safe location for future recalibration needs and mark it with robot serial
number to ensure that the correct one is refitted.
Spare parts
When calibration is not being performed, a protective cover and an o-ring should
always be installed on the fixed calibration pin as well as a protective plug, included
a sealing, in the bushing. Replace damaged parts with new, if needed.
Note
Article number
Spare part
Contains replacement calibration
pin covers and protective plugs
for the bushing.
3HAC056806-001
Protection cover and plug set
356
Product manual - IRB 6660
3HAC028197-001 Revision: S
© Copyright 2007-2018 ABB. All rights reserved.
5 Calibration
5.4.3 Installation locations for the calibration tools
Содержание IRB 6660
Страница 1: ...ROBOTICS Product manual IRB 6660 ...
Страница 2: ...Trace back information Workspace R18 2 version a18 Checked in 2018 11 20 Skribenta version 5 3 012 ...
Страница 8: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 48: ...This page is intentionally left blank ...
Страница 108: ...This page is intentionally left blank ...
Страница 172: ...This page is intentionally left blank ...
Страница 366: ...This page is intentionally left blank ...
Страница 386: ...This page is intentionally left blank ...
Страница 388: ...This page is intentionally left blank ...
Страница 394: ......
Страница 395: ......