4.4.5 Replacement of lower arm shaft
Prerequisites
This section details how to remove and refit the lower arm shaft as a step in the
procedure of removing/refitting the complete lower arm. To perform the procedure
described in this section, it is required that the preceding instructions in section
Replacement of complete lower arm on page 273
are followed! These include:
•
removing the upper arm
•
removing the cabling in the lower arm
•
unloading the balancing device and removing the front eye shaft
•
draining the oil in gearbox axis 2
•
unloading the lower arm with specific lifting equipment.
Components, lower arm shaft for robots with protection Standard
The figure shows components fitted to the lower arm shaft when the robot has
protection Standard.
The figure shows IRB 6600, but is also valid for IRB 6650S!
xx0300000487
Protection plug
A
Lower arm shaft (axis 2 shaft)
B
Thrust washer
C
Bearing
D
Protection washer
E
Retaining ring
F
Continues on next page
Product manual - IRB 6650S
283
3HAC020993-001 Revision: Z
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.4.5 Replacement of lower arm shaft
Содержание IRB 6650S Series
Страница 1: ...ROBOTICS Product manual IRB 6650S ...
Страница 2: ...Trace back information Workspace R18 2 version a18 Checked in 2018 11 20 Skribenta version 5 3 012 ...
Страница 20: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 210: ...This page is intentionally left blank ...
Страница 416: ...This page is intentionally left blank ...
Страница 422: ...This page is intentionally left blank ...
Страница 426: ...This page is intentionally left blank ...
Страница 449: ......