Removal, balancing device
The procedure below details how to remove the balancing device.
Info/Illustration
Action
WARNING
Do not
under any circumstances, deal with
the balancing device in any other way than
that detailed in the product documentation!
For example, attempting to open the balan-
cing device is potentially lethal!
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply (do not turn off
for Foundry Prime robots!)
to the robot, before entering the robot
working area.
2
CAUTION
The balancing device weighs 50 kg.
All lifting accessories used must be sized
accordingly!
3
xx0300000088
Move the manipulator to the calibration pos-
ition, as shown in the figure to the right.
4
•
A: Approximately 2º
Continues on next page
200
Product manual - IRB 4400
3HAC022032-001 Revision: Q
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.6.1 Replacement of balancing device
Continued