3.2.2 Maintenance schedule
General
The robot must be maintained regularly to ensure proper function. The maintenance
activities and intervals are specified in the table below.
Non-predictable situations also give rise to inspections of the robot. Any damages
must be attended to immediately!
The inspection intervals
do not
specify the life of each component.
Activities and intervals, standard equipment
The table below specifies the required maintenance activities and intervals and
also refers to the section where performing the activity is detailed.
Detailed in section:
Note
Interval
Maintenance activity
Lubricated for life.
Maintenance free units.
40000 h
Oil change in gearboxes,
axes 1,2, 3
Oil change, gearbox
axis 6 (wrist unit) on
page 102
No preventive mainten-
ance in terms of chan-
ging the gear oil is
needed when gearbox
is lubricated with Shell
Tivela S 150.
-
Oil change in wrist unit
Replacement of SMB
battery on page 104
.
Battery pack, measure-
ment system with 2-
pole battery contact,
e.g. DSQC633A
Battery low
alert
i
Replacement of battery
pack, SMB unit
Replacement of SMB
battery on page 104
.
Battery pack, measure-
ment system of type
RMU101 or RMU102 (3-
pole battery contact)
36 months or
battery low
alert
ii
Replacement of battery
pack, SMB unit
Replace if required.
36 mths
Inspection of all signal
cabling in lower and up-
per arm
Replace if bent.
60 mths
Replacement of mechan-
ical stop axis 1
i
The battery low alert (38213
Battery charge low
) is displayed when remaining backup capacity
(robot powered off) is less than 2 months. The typical lifetime of a new battery is 36 months if the
robot is powered off 2 days/week or 18 months if the robot is powered off 16 h/day. The lifetime
can be extended with a battery shutdown service routine. See
Operating manual - IRC5 with
FlexPendant
for instructions.
ii
The battery low alert (38213
Battery charge low
) is displayed when the battery needs to be replaced.
The recommendation to avoid an unsynchronized robot is to keep the power to the controller turned
on until the battery is to be replaced.
See the replacement instruction for more details.
3HAC026048-001 Revision: E
97
© Copyright 2006-2013 ABB. All rights reserved.
3 Maintenance
3.2.2 Maintenance schedule
Содержание IRB 260
Страница 1: ...ABB Robotics Product manual IRB 260 ...
Страница 2: ...Trace back information Workspace R13 1 version a6 Checked in 2013 03 31 Skribenta version 1184 ...
Страница 8: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 214: ...This page is intentionally left blank ...
Страница 216: ...This page is intentionally left blank ...
Страница 260: ...This page is intentionally left blank ...
Страница 266: ......
Страница 267: ......