2.3.3 Orienting and securing the robot
General
This section details how to orient and secure the robot to the foundation in order
to safely run the robot. The requirements for the foundations are shown in the
tables and figures below.
Bolting requirements
When bolting a base plate or the base to a concrete floor, follow the general
instructions for expansion-shell bolts. The screw joint must be able to withstand
the stress loads defined in section
Pre-installation procedure on page 54
.
Attachment screws
The table below specifies the type of securing screws and washers to be used for
securing the robot to the base plate/foundation.
M16 x 50
Suitable screws, lightly lubricated:
Quality 8.8
Quality
Thickness: 3 mm
Suitable washer:
Outer diameter: 30 mm
Inner diameter: 17 mm
190 Nm
Tightening torque:
Continues on next page
66
3HAC026048-001 Revision: E
© Copyright 2006-2013 ABB. All rights reserved.