![ABB IRB 2400 Series Скачать руководство пользователя страница 140](http://html.mh-extra.com/html/abb/irb-2400-series/irb-2400-series_product-manual_5033140.webp)
Refitting, wrist unit
The procedure below details how to refit the wrist unit to the robot.
Note
Action
DANGER
Turn off all electric power, hydraulic and pneumatic
pressure supplies to the robot!
1
Clean the surface of the tubular shaft.
2
Apply Loctite 574 all around.
3
Tightening torque: 8.3 Nm +10%.
Fit the wrist, tighten the attachment screws.
4
Screw the clamping sleeves together using screws
to a torque of 5.7 Nm.
5
Refit the plugs.
6
Refit the cover at the motor side of axis 5-6.
7
Calibration is detailed in a separate
calibration manual enclosed with
the calibration tools.
Calibrate the robot!
8
General calibration information is
included in the section
.
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in the section
9
140
Product manual - IRB 2400
3HAC022031-001 Revision: P
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.4.2 Replacement of wrist IRB 2400L
Continued
Содержание IRB 2400 Series
Страница 1: ...ROBOTICS Product manual IRB 2400 ...
Страница 2: ...Trace back information Workspace R18 1 version a9 Checked in 2018 03 22 Skribenta version 5 2 025 ...
Страница 8: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 204: ...This page is intentionally left blank ...
Страница 220: ...This page is intentionally left blank ...
Страница 232: ...This page is intentionally left blank ...
Страница 234: ...This page is intentionally left blank ...
Страница 240: ......
Страница 241: ......